Author: Su, Lan; Wang, Songjie; Wu, Shengjie; Xu, Lei; Huang, Zhouqing; Chen, Xiao; Zheng, Rujie; Jiang, Limeng; Ellenbogen, Kenneth A; Whinnett, Zachary I; Huang, Weijian
Title: Long-term Safety and Feasibility of Left Bundle Branch Pacing in A Large Single Center Study. Cord-id: nv2pdcaa Document date: 2021_1_9
ID: nv2pdcaa
Snippet: Background - Left bundle branch pacing (LBBP) is a novel pacing method and has been observed to have low and stable pacing thresholds in prior small short-term studies. The objective of this study was to evaluate the feasibility and safety of LBBP in a large consecutive diverse group of patients with long-term follow up. Methods - This study prospectively enrolled 632 consecutive pacemaker patients with attempted LBBP from April 2017 to July 2019. Pacing parameters, complications, ECG, and echoc
Document: Background - Left bundle branch pacing (LBBP) is a novel pacing method and has been observed to have low and stable pacing thresholds in prior small short-term studies. The objective of this study was to evaluate the feasibility and safety of LBBP in a large consecutive diverse group of patients with long-term follow up. Methods - This study prospectively enrolled 632 consecutive pacemaker patients with attempted LBBP from April 2017 to July 2019. Pacing parameters, complications, ECG, and echocardiographic measurements were assessed at implant, and during follow-up of 1, 6, 12 and 24 months. Results - LBBP was successful in 618/632 (97.8%) patients according to strict criteria for LBB capture. Mean follow-up time was 18.6±6.7 months. 231 patients had follow-up over 2 years. LBB capture threshold at implant was 0.65±0.27 mV@0.5ms and 0.69±0.24 mV@0.5ms at 2-year follow-up. A significant decrease in QRS duration was observed in patients with LBBB (167.22 ± 18.99ms vs. 124.02 ± 24.15ms, p<0.001). Post implantation left ventricular ejection fraction improved in patients with QRS≥120ms (48.82±17.78 % vs. 58.12±13.04 %, p<0.001). The number of patients with moderate and severe tricuspid regurgitation decreased at 1-year. Permanent right bundle branch injury occurred in 55 (8.9%) patients. LBB capture threshold increased to more than 3 V or loss of bundle capture in 6 patients (1%), 2 patients of them had loss of conduction system capture. Two patients required lead revision due to dislodgement. Conclusions - This large observational study suggests that LBBP is feasible with high success rates and low complication rates during long term follow up. Therefore, LBBP appears to be a reliable method for physiological pacing for patients with either a bradycardia or heart failure pacing indication.
Search related documents:
Co phrase search for related documents- long term patient and low complication rate: 1
Co phrase search for related documents, hyperlinks ordered by date