Selected article for: "amplification signal and negative sample"

Author: Mauricio J Farfan; Juan P Torres; Miguel ORyan; Mauricio Olivares; Pablo Gallardo; Carolina Salas
Title: Optimizing RT-PCR detection of SARS-CoV-2 for developing countries using pool testing
  • Document date: 2020_4_17
  • ID: kuqinczz_14
    Snippet: To test the efficiency of our previous data, 20 new pools were prepared. Pools 13 to 26 included 4 negative samples and 1 positive sample with CT ranging from 16.6 to 36.1; pools 27 to 31 included 5 negative samples. Extraction of nucleic acid from pools were done by manual extraction. SARS-CoV-2 amplification was observed in pools 13 to 25, observing an increase of CT values from 1 to 4.5. No amplification signal was detected in pool 26, which i.....
    Document: To test the efficiency of our previous data, 20 new pools were prepared. Pools 13 to 26 included 4 negative samples and 1 positive sample with CT ranging from 16.6 to 36.1; pools 27 to 31 included 5 negative samples. Extraction of nucleic acid from pools were done by manual extraction. SARS-CoV-2 amplification was observed in pools 13 to 25, observing an increase of CT values from 1 to 4.5. No amplification signal was detected in pool 26, which include a positive sample with a CT=36.1. Pools 27 to 31 were all RT-PCR negative ( Figure 2 ).

    Search related documents:
    Co phrase search for related documents
    • amplification signal and CT value: 1, 2, 3, 4
    • amplification signal and manual extraction: 1
    • amplification signal and negative sample: 1
    • amplification signal and nucleic acid: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • amplification signal and nucleic acid extraction: 1
    • amplification signal and positive sample: 1, 2
    • amplification signal and positive sample include: 1
    • amplification signal and SARS amplification: 1, 2, 3, 4, 5, 6, 7, 8
    • CT positive sample and CT value: 1, 2, 3, 4, 5, 6, 7, 8
    • CT positive sample and manual extraction: 1
    • CT positive sample and negative sample: 1, 2, 3, 4
    • CT positive sample and nucleic acid: 1, 2
    • CT positive sample and positive sample: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18
    • CT positive sample and positive sample include: 1
    • CT positive sample and SARS amplification: 1, 2
    • CT value and manual extraction: 1
    • CT value and negative sample: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    • CT value and nucleic acid: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • CT value and nucleic acid extraction: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15