Author: Brown, Julianne R.; O’Sullivan, Denise M.; Shah, Divya; Atkinson, Laura; Pereira, Rui P.A.; Whale, Alexandra S.; Busby, Eloise J.; Huggett, Jim F.; Harris, Kathryn
Title: Comparison of SARS-CoV-2 N gene real-time RT-PCR targets and commercially available mastermixes Cord-id: fxxt3zp2 Document date: 2021_6_21
ID: fxxt3zp2
Snippet: BACKGROUND: This study aimed to evaluate the impact of four different reverse transcription quantitative PCR (RT-qPCR) master mixes on the performance of SARS-CoV-2 diagnostic PCRs using three primer/probe assays targeting the N gene (A, B and C). The dynamic range and lowest detected quantity was determined using a SARS-CoV-2 partial N gene RNA transcript dilution series (100,000–1 copy/μl) and verified using 72 nose and throat swabs, 29 of which tested positive for SARS-CoV-2 RNA. RESULTS:
Document: BACKGROUND: This study aimed to evaluate the impact of four different reverse transcription quantitative PCR (RT-qPCR) master mixes on the performance of SARS-CoV-2 diagnostic PCRs using three primer/probe assays targeting the N gene (A, B and C). The dynamic range and lowest detected quantity was determined using a SARS-CoV-2 partial N gene RNA transcript dilution series (100,000–1 copy/μl) and verified using 72 nose and throat swabs, 29 of which tested positive for SARS-CoV-2 RNA. RESULTS: Assay C consistently detected the lowest quantity of partial N gene RNA transcript with all mastermixes. The Takara One Step PrimeScript™ III RT-PCR Kit mastermix enabled all primer pairs to detect the entire dynamic range evaluated, with the Qiagen Quantifast and Thermofisher TaqPath 1-Step kits also performing well. Sequences from all three primer/probe sets tested in this study (assay A, B and C) have 100 % homology to ≥97 % of the of SARS-CoV-2 sequences available up to 31st December 2020 (n = 291,483 sequences). CONCLUSIONS: This work demonstrates that specific assays (in this case assay C) can perform well in terms of dynamic range and lowest detected quantity regardless of the mastermix used. However we also show that, by choosing the most appropriate mastermix, poorer performing primer pairs are also able to detect all of the template dilutions investigated. This work increases the potential options when choosing assays for SARS-CoV-2 diagnosis and provides solutions to enable them to work with optimal analytical sensitivity.
Search related documents:
Co phrase search for related documents- accurate diagnosis and additional detection: 1, 2, 3
- accurate diagnosis and lod detection: 1, 2, 3, 4, 5
- accurate diagnosis and lod detection limit: 1, 2, 3, 4, 5
- accurate diagnosis and low quality: 1, 2, 3, 4, 5, 6
- acid extraction and lod detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
- acid extraction and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
- additional detection and lod detection: 1
- additional detection and lod detection limit: 1
- additional detection and low quality: 1
Co phrase search for related documents, hyperlinks ordered by date