Selected article for: "PCR assay and primer set"

Author: Yoda, Tomoko; Suzuki, Yasuhiko; Yamazaki, Kenji; Sakon, Naomi; Kanki, Masashi; Aoyama, Ikuko; Tsukamoto, Teizo
Title: Evaluation and application of reverse transcription loop‐mediated isothermal amplification for detection of noroviruses
  • Cord-id: lshsgex3
  • Document date: 2007_1_23
  • ID: lshsgex3
    Snippet: A one‐step reverse transcription loop‐mediated isothermal amplification (RT‐LAMP) assay for the detection of norovirus (NV) was developed. In order to design primer sets for the detection of a wide range of NVs, NVs were categorized into three groups, that is, genogroup I (GI), prevalent GII, and minor GII; three sets of primers were developed for each group. Clinical specimens of patients suffering from enteric RNA viruses, such as NV, group A and C rotavirus, and sapovirus were examined
    Document: A one‐step reverse transcription loop‐mediated isothermal amplification (RT‐LAMP) assay for the detection of norovirus (NV) was developed. In order to design primer sets for the detection of a wide range of NVs, NVs were categorized into three groups, that is, genogroup I (GI), prevalent GII, and minor GII; three sets of primers were developed for each group. Clinical specimens of patients suffering from enteric RNA viruses, such as NV, group A and C rotavirus, and sapovirus were examined using these primer sets. Various genotypes of NVs were detected in clinical specimens from patients infected with NV where no false positive reaction was observed with other enteric RNA viruses. Additionally, 88 samples of acute gastroenteritis outbreaks were analyzed by an RT‐LAMP assay and compared with the results of routine RT‐PCR. The results of the RT‐LAMP assay corresponded well to that of RT‐PCR. These findings suggest the practical application of the RT‐LAMP assay for the detection of NVs in clinical specimens. Consequently, the RT‐LAMP system and conventional detection kits (NVGI and NVGII detection kits; Eiken Chemical Co., Ltd., Japan) were compared. The detection rate of the prevalent and minor GII primer sets was similar to that of the conventional NVGII kit, while the detection rate of the GI primer set is different because it can detect several genotypes better than the conventional NVGI kit. This is an initial report that the RT‐LAMP system is able to detect NVs in clinical specimens within a wide range. J. Med. Virol. 79:326–334, 2007. © 2007 Wiley‐Liss, Inc.

    Search related documents:
    Co phrase search for related documents
    • accession number and acute respiratory syndrome coronavirus: 1, 2, 3
    • accession number and loop primer: 1
    • accession number and loopamp real time turbidimeter: 1
    • accession number and ma ipswich: 1
    • accession number and ma ipswich new england biolabs: 1
    • accurate method and acute outbreak: 1, 2, 3, 4
    • accurate method and acute respiratory: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • accurate method and acute respiratory syndrome coronavirus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acute respiratory and additional treatment: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acute respiratory and loop primer: 1, 2, 3, 4, 5
    • acute respiratory syndrome coronavirus and additional treatment: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24
    • acute respiratory syndrome coronavirus and loop primer: 1, 2, 3
    • loop primer and ma ipswich: 1