Author: Glineur, David; Hendrikx, Marc; Krievins, Dainis; Stradins, Peteris; Voss, Bernhard; Waldow, Thomas; Haenen, Luc; Oberhoffer, Martin; Ritchie, Caroline M
                    Title: A randomized, controlled trial of Verisetâ„¢ hemostatic patch in halting cardiovascular bleeding.  Cord-id: pl580to5  Document date: 2018_1_1
                    ID: pl580to5
                    
                    Snippet: Background Obtaining hemostasis during cardiovascular procedures can be a challenge, particularly around areas with a complex geometry or that are difficult to access. While several topical hemostats are currently on the market, most have caveats that limit their use in certain clinical scenarios such as pulsatile arterial bleeding. The aim of this study was to assess the effectiveness and safety of Verisetâ„¢ hemostatic patch in treating cardiovascular bleeding. Methods Patients (N=90) schedule
                    
                    
                    
                     
                    
                    
                    
                    
                        
                            
                                Document: Background Obtaining hemostasis during cardiovascular procedures can be a challenge, particularly around areas with a complex geometry or that are difficult to access. While several topical hemostats are currently on the market, most have caveats that limit their use in certain clinical scenarios such as pulsatile arterial bleeding. The aim of this study was to assess the effectiveness and safety of Veriset™ hemostatic patch in treating cardiovascular bleeding. Methods Patients (N=90) scheduled for cardiac or vascular surgery at 12 European institutions were randomized 1:1 to treatment with either Veriset™ hemostatic patch (investigational device) or TachoSil® (control). After application of the hemostat, according to manufacturer instructions for use, time to hemostasis was monitored. Follow-up occurred up to 90 days post-surgery. Results Median time to hemostasis was 1.5 min with Veriset™ hemostatic patch, compared to 3.0 min with TachoSil® (p<0.0001). Serious adverse events within 30 days post-surgery were experienced by 12/44 (27.3%) patients treated with Veriset™ hemostatic patch and 10/45 (22.2%) in the TachoSil® group (p=0.6295). None of these adverse events were device-related, and no reoperations for bleeding were required within 5 days post-surgery in either treatment group. Conclusion This study reinforces the difference in minimum recommended application time between Veriset™ hemostatic patch and TachoSil® (30 s versus 3 min respectively). When compared directly at 3 min, Veriset™ displayed no significant difference, showing similar hemostasis and safety profiles on the cardiovascular bleeding sites included in this study.
 
  Search related documents: 
                                Co phrase  search for related documents- Try single phrases listed below for: 1
  
 
                                Co phrase  search for related documents, hyperlinks ordered by date