Author: Kim, Hanah; Hur, Mina; Moon, Heeâ€Won; Yun, Yeoâ€Min; Cho, Hyun Chan
Title: Comparison of two multiplex PCR assays for the detection of respiratory viral infections Cord-id: q0voqbsg Document date: 2014_1_10
ID: q0voqbsg
Snippet: INTRODUCTION: Respiratory viruses are the main causes of upper and lower respiratory tract diseases. Rapid and accurate detection of respiratory viruses is crucial for appropriate patient treatment and prevention of endemic spread. OBJECTIVES: We compared two multiplex polymerase chain reaction (PCR) assays for the detection of respiratory viral pathogens. METHODS: A total of 245 respiratory specimens (229 sputum samples, 14 bronchoalveolar lavage samples, 6 nasal swabs, 3 throat swabs, 7 unknow
Document: INTRODUCTION: Respiratory viruses are the main causes of upper and lower respiratory tract diseases. Rapid and accurate detection of respiratory viruses is crucial for appropriate patient treatment and prevention of endemic spread. OBJECTIVES: We compared two multiplex polymerase chain reaction (PCR) assays for the detection of respiratory viral pathogens. METHODS: A total of 245 respiratory specimens (229 sputum samples, 14 bronchoalveolar lavage samples, 6 nasal swabs, 3 throat swabs, 7 unknown) were analyzed using two multiplex assays: Oneâ€step RV realâ€time PCR (BioSewoom, Seoul, Korea) and Seeplex RV 12 Detection kit (Seegene, Seoul, Korea). The results were further confirmed using sequencing as a reference. RESULTS: Among 245 samples (265 identifications including coâ€infections), the identification of respiratory viruses was 44.9% (119/265), 44.2% (117/265) and 45.3% (120/265) by Oneâ€step RV assay, Seeplex RV assay and sequencing, respectively. The concordance rate between Oneâ€step RV assay and sequencing was 95.5% (253/265), and that between Seeplex RV assay and sequencing was 89.8% (238/265) (P = 0.0189). The sensitivities of Oneâ€step RV and Seeplex RV assays were 94.1% [95% confidential interval (CI), 88.3%–97.6%] and 83.3% (95% CI, 75.4%–89.5%), respectively (P = 0.0002). The specificities of Oneâ€step RV and Seeplex RV assays were 96.6% (95% CI, 92.2%–98.9%) and 95.2% (95% CI, 90.3%–98.0%), respectively. CONCLUSION: Although the performances of Oneâ€step RV and Seeplex RV assays were overall comparable, Oneâ€step RV assay showed better sensitivity and concordance with sequencing. Oneâ€step RV assay can be a useful option for respiratory virus testing in clinical laboratories.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date