Author: Chan, Maurice; Koo, Seok Hwee; Jiang, Boran; Lim, Pei Qi; Tan, Thean Yen
Title: Comparison of the Biofire FilmArray Respiratory Panel, Seegene AnyplexII RV16, and Argene for the detection of respiratory viruses Cord-id: q9ij2skz Document date: 2018_7_6
ID: q9ij2skz
Snippet: BACKGROUND: Respiratory infections are common reasons for hospital admission, and are associated with enormous economic burden due to significant morbidity and mortality. The wide spectrum of microbial agents underlying the pathology renders the diagnosis of respiratory infections challenging. Molecular diagnostics offer an advantage to the current serological and culture-based methods in terms of sensitivity, coverage, hands-on time, and time to results. OBJECTIVES: This study aimed to compare
Document: BACKGROUND: Respiratory infections are common reasons for hospital admission, and are associated with enormous economic burden due to significant morbidity and mortality. The wide spectrum of microbial agents underlying the pathology renders the diagnosis of respiratory infections challenging. Molecular diagnostics offer an advantage to the current serological and culture-based methods in terms of sensitivity, coverage, hands-on time, and time to results. OBJECTIVES: This study aimed to compare the clinical performance of three commercial kits for respiratory viral detection. STUDY DESIGN: The performance of FilmArray Respiratory Panel, AnyplexII RV16, and Argene was compared using clinical respiratory samples (n = 224, comprising 189 nasopharyngeal swabs in Universal Transport Medium (UTM) and 35 endotracheal aspirates), based on common overlapping targets across the platforms. Influenza A “equivocal†and “no-subtype†samples by FilmArray were further compared to a laboratory-developed Influenza A/B test. RESULTS AND CONCLUSIONS: The overall performance of all three platforms appeared to be comparable with regards to sensitivities (95.8–97.9%) and specificities (96.1–98.0%), detection of coinfections, and distinguishment of influenza from non-influenza cases. “Equivocal†and “no-subtype†samples by FilmArray mostly represented weak Influenza A by laboratory-developed test. Lower respiratory tract samples had comparable final-run success-rates and discordant-rates as compared to UTM. Coronavirus HKU1, which was not targeted by AnyplexII RV16, were detected as OC43. The expected test volume would be the main determinant for the selection of platform. Among the platforms, the FilmArray is the most automated but is of the lowest-throughput and has the highest reagent cost.
Search related documents:
Co phrase search for related documents- accurately diagnose and acid amplification: 1, 2, 3
- accurately diagnose and acid detection: 1, 2
- accurately diagnose and adenovirus bocavirus: 1
- accurately diagnose and low sensitivity: 1
- acid amplification and adenovirus bocavirus: 1
- acid amplification and adenovirus detection: 1, 2
- acid amplification and adenovirus testing: 1
- acid amplification and long turnaround time: 1, 2, 3, 4
- acid amplification and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20
- acid amplification and low specificity: 1, 2, 3, 4, 5, 6
- acid amplification and luminex fast xtag rvp: 1
- acid amplification and luminex molecular diagnostics: 1, 2
- acid amplification and luminex xtag fast rvp: 1
- acid amplification and luminex xtag rvp: 1, 2, 3, 4
- acid detection and adenovirus detection: 1
- acid detection and low complexity: 1
- acid detection and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
- acid detection and low specificity: 1, 2, 3, 4, 5
- acid detection and luminex fast xtag rvp: 1
Co phrase search for related documents, hyperlinks ordered by date