Selected article for: "detection limit and ELISA immunosorbent assay"

Author: Huang, Jason C.; Chang, Ying-Feng; Chen, Kuan-Hsuan; Su, Li-Chen; Lee, Chun-Wei; Chen, Chii-Chang; Chen, Yi-Ming Arthur; Chou, Chien
Title: Detection of severe acute respiratory syndrome (SARS) coronavirus nucleocapsid protein in human serum using a localized surface plasmon coupled fluorescence fiber-optic biosensor
  • Cord-id: qvhu7mos
  • Document date: 2009_10_15
  • ID: qvhu7mos
    Snippet: In order to enhance the sensitivity of conventional immunoassay technology for the detection of SARS coronavirus (SARS-CoV) nucleocapsid protein (N protein), we developed a localized surface plasmon coupled fluorescence (LSPCF) fiber-optic biosensor that combines sandwich immunoassay with the LSP technique. Experimentally, a linear relationship between the fluorescence signal and the concentration of recombinant SARS-CoV N (GST-N) protein in buffer solution could be observed from 0.1 pg/mL to 1
    Document: In order to enhance the sensitivity of conventional immunoassay technology for the detection of SARS coronavirus (SARS-CoV) nucleocapsid protein (N protein), we developed a localized surface plasmon coupled fluorescence (LSPCF) fiber-optic biosensor that combines sandwich immunoassay with the LSP technique. Experimentally, a linear relationship between the fluorescence signal and the concentration of recombinant SARS-CoV N (GST-N) protein in buffer solution could be observed from 0.1 pg/mL to 1 ng/mL. In addition, the concentration of GST-N protein in diluted serum across a similar range could also be measured. The correlation coefficients (linear scale) for these two measurements were 0.9469 and 0.9624, respectively. In comparison with conventional enzyme linked immunosorbent assay (ELISA), the detection limit of the LSPCF fiber-optic biosensor for the GST-N protein was improved at least 10(4)-fold using the same monoclonal antibodies. Therefore, the LSPCF fiber-optic biosensor shows an ability to detect very low concentration (∼1 pg/mL) of SARS-CoV N protein in serum. The biosensor should help with the early diagnosis of SARS infection.

    Search related documents:
    Co phrase search for related documents
    • accurate rapid and acute sars respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • accurate rapid and low concentration: 1, 2, 3, 4, 5, 6, 7
    • accurate rapid and low concentration detect: 1
    • accurate rapid and low detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • accurate rapid and low detection limit: 1, 2, 3, 4, 5
    • accurate rapid diagnostic method and acute sars respiratory syndrome: 1
    • accurate rapid diagnostic method and low concentration: 1
    • acid detection and acute phase: 1, 2, 3
    • acid detection and acute sars respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acid detection and low concentration: 1, 2
    • acid detection and low detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acid detection and low detection limit: 1, 2, 3, 4
    • acute phase and low concentration: 1, 2, 3
    • acute phase and low detection: 1, 2
    • acute sars respiratory syndrome and low concentration: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acute sars respiratory syndrome and low concentration detect: 1, 2, 3
    • acute sars respiratory syndrome and low detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acute sars respiratory syndrome and low detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9