Author: Jariyakosol, Supharat; Jaru-ampornpan, Patcharaporn; Manassakorn, Anita; Itthipanichpong, Rath; Hirunwiwatkul, Parima; Tantisevi, Visanee; Somkijrungroj, Thanapong; Rojanapongpun, Prin
Title: Sensitivity and Specificity of New Visual Field Screening Software for Diagnosing Hemianopia Cord-id: qzy7e920 Document date: 2021_8_29
ID: qzy7e920
Snippet: PURPOSE: To assess the diagnostic accuracy of visual field results generated by the newly developed software (CU-VF) and the standard automated perimetry (SAP) for detecting hemianopia. PATIENTS AND METHODS: Forty-three subjects with hemianopia and 33 controls were tested with the CU-VF software on a personal computer and SAP. Hemianopia was defined as the presence of a hemianopic field respecting the vertical meridian on SAP with the corresponding neuroimaging pathology as evaluated by 2 neuro-
Document: PURPOSE: To assess the diagnostic accuracy of visual field results generated by the newly developed software (CU-VF) and the standard automated perimetry (SAP) for detecting hemianopia. PATIENTS AND METHODS: Forty-three subjects with hemianopia and 33 controls were tested with the CU-VF software on a personal computer and SAP. Hemianopia was defined as the presence of a hemianopic field respecting the vertical meridian on SAP with the corresponding neuroimaging pathology as evaluated by 2 neuro-ophthalmologists. Results of CU-VF were independently evaluated by 2 neuro-ophthalmologists, 1 general ophthalmologist, and 1 general practitioner in terms of the presence of hemianopia. Sensitivity, specificity, and kappa coefficient for inter-observer reliability were calculated. Satisfaction and ease of use were evaluated with a visual analog-scale questionnaire and analyzed using paired t-test. RESULTS: The sensitivity (95% CI) and specificity (95% CI) of the CU-VF to detect hemianopia was 74.42% (58.53–85.96) and 93.94% (78.38–99.94). Kappa coefficient between neuro-ophthalmologists versus general ophthalmologist and general practitioner were 0.71 and 0.84, respectively. The mean (SD) test duration was 2.25 (0.002) minutes for the CU-VF and 5.38 (1.34) minutes for SAP (p < 0.001). Subjects reported significantly higher satisfaction and comfort using the CU-VF software compared to SAP. CONCLUSION: The CU-VF screening software showed good validity and reliability to detect hemianopia, with shorter test duration and higher subject satisfaction compared to SAP.
Search related documents:
Co phrase search for related documents- abnormal point and magnetic resonance: 1, 2
- absence presence and acceptable sensitivity: 1
- absence presence and accurate reliable: 1
- absence presence and low reliability: 1, 2
- absence presence and low sensitivity: 1, 2, 3, 4, 5, 6, 7
- absence presence and low specificity: 1, 2
- absence presence and magnetic resonance: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
- acceptable sensitivity and low sensitivity: 1, 2, 3, 4
- acceptable sensitivity and low specificity: 1
- accurate reliable and low sensitivity: 1
- accurate reliable and magnetic resonance: 1, 2, 3, 4, 5
- low sensitivity and magnetic resonance: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- low specificity and magnetic resonance: 1, 2, 3
Co phrase search for related documents, hyperlinks ordered by date