Author: Lee, Szu-Yuan; Huang, Jhen-Gang; Chuang, Tsung-Liang; Sheu, Jin-Chuan; Chuang, Yi-Kuang; Holl, Mark; Meldrum, Deirdre R.; Lee, Chun-Nan; Lin, Chii-Wann
                    Title: Compact optical diagnostic device for isothermal nucleic acids amplification  Cord-id: tcvs4beg  Document date: 2008_8_12
                    ID: tcvs4beg
                    
                    Snippet: We recently reported the successful use of the loop-mediated isothermal amplification (LAMP) reaction for hepatitis B virus (HBV) DNA amplification and its optimal primer design method. In this study, we report the development of an integrated isothermal device for both amplification and detection of targeted HBV DNA. It has two major components, a disposable polymethyl methacrylate (PMMA) micro-reactor and a temperature-regulated optical detection unit (base apparatus) for real-time monitoring 
                    
                    
                    
                     
                    
                    
                    
                    
                        
                            
                                Document: We recently reported the successful use of the loop-mediated isothermal amplification (LAMP) reaction for hepatitis B virus (HBV) DNA amplification and its optimal primer design method. In this study, we report the development of an integrated isothermal device for both amplification and detection of targeted HBV DNA. It has two major components, a disposable polymethyl methacrylate (PMMA) micro-reactor and a temperature-regulated optical detection unit (base apparatus) for real-time monitoring of the turbidity changes due to the precipitation of DNA amplification by-product, magnesium pyrophosphate. We have established a correlation curve (R(2) = 0.99) between the concentration of pyrophosphate ions and the level of turbidity by using a simulated chemical reaction to evaluate the characteristics of our device. For the applications of rapid pathogens detection, we also have established a standard curve (R(2) = 0.96) by using LAMP reaction with a standard template in our device. Moreover, we also have successfully used the device on seven clinical serum specimens where HBV DNA levels have been confirmed by real-time PCR. The result indicates that different amounts of HBV DNA can be successfully detected by using this device within 1 h.
 
  Search related documents: 
                                Co phrase  search for related documents- accurate rapid and acid amplification: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37
  - accurate rapid and acid amplification method: 1, 2, 3, 4, 5, 6, 7
  - accurate rapid and acid sequence: 1, 2, 3
  - accurate rapid and acute infectious disease: 1, 2
  - accurate rapid and liver disease: 1, 2
  - accurate rapid and low cost device: 1, 2, 3, 4, 5
  
 
                                Co phrase  search for related documents, hyperlinks ordered by date