Author: Soon Keong Wee; Suppiah Paramalingam Sivalingam; Eric Peng Huat Yap
                    Title: Rapid direct nucleic acid amplification test without RNA extraction for SARS-CoV-2 using a portable PCR thermocycler  Document date: 2020_4_20
                    ID: e1oinu71_22
                    
                    Snippet: The limit of detection (LoD) was determined by plotting quantification cycle (Cq) against log10 copy number concentration. Correlation coefficient (R 2 ) was calculated by linear regression analysis. Amplification efficiency (E) was calculated from the slope of the log-linear curve using the given equation: E = -1+10 (-1/slope) . The slopes and intercepts of the linear regression lines were tested for statistical significance using Analysis of Co.....
                    
                    
                    
                     
                    
                    
                    
                    
                        
                            
                                Document: The limit of detection (LoD) was determined by plotting quantification cycle (Cq) against log10 copy number concentration. Correlation coefficient (R 2 ) was calculated by linear regression analysis. Amplification efficiency (E) was calculated from the slope of the log-linear curve using the given equation: E = -1+10 (-1/slope) . The slopes and intercepts of the linear regression lines were tested for statistical significance using Analysis of Covariance (ANCOVA) (GraphPad Prism 6). Repeatability and reproducibility of the RT-qPCR assay was determined by analysing the mean values and standard deviations of Cq values.
 
  Search related documents: 
                                Co phrase  search for related documents- amplification efficiency and correlation coefficient: 1, 2, 3, 4, 5, 6
  - amplification efficiency and Cq value: 1
  - amplification efficiency and linear regression: 1
  - amplification efficiency and LoD detection: 1, 2
  - amplification efficiency and LoD detection limit: 1, 2
  - amplification efficiency and mean value: 1
  - amplification efficiency and regression analysis: 1
  - amplification efficiency and reproducibility repeatability: 1
  - amplification efficiency and standard deviation: 1
  - ANCOVA Covariance Analysis and linear regression: 1, 2, 3
  - ANCOVA Covariance Analysis and linear regression analysis: 1, 2
  - ANCOVA Covariance Analysis and mean value: 1
  - ANCOVA Covariance Analysis and regression analysis: 1, 2, 3, 4, 5, 6, 7
  - copy number and correlation coefficient: 1, 2, 3
  - copy number and Cq quantification cycle: 1, 2
  - copy number and Cq value: 1, 2, 3, 4
  - copy number and linear regression: 1, 2, 3, 4, 5, 6
  - copy number and linear regression analysis: 1, 2, 3
  - copy number and linear regression line: 1
  
 
                                Co phrase  search for related documents, hyperlinks ordered by date