Selected article for: "lod detection and log concentration range"

Author: Soon Keong Wee; Suppiah Paramalingam Sivalingam; Eric Peng Huat Yap
Title: Rapid direct nucleic acid amplification test without RNA extraction for SARS-CoV-2 using a portable PCR thermocycler
  • Document date: 2020_4_20
  • ID: e1oinu71_15
    Snippet: The lowest limit of detection (LoD) was determined using SARS-CoV-2 N RNA template that was ten-fold serially diluted in SARS-CoV-2-negative sputum and nasal exudate samples. LoD was defined as the last dilution in which quantification cycle (Cq) value could be detected in all replicates. The linear range correlation between the theoretical log copy number calculated from the concentration molarity of synthetic nucleic acids and Cq value was esta.....
    Document: The lowest limit of detection (LoD) was determined using SARS-CoV-2 N RNA template that was ten-fold serially diluted in SARS-CoV-2-negative sputum and nasal exudate samples. LoD was defined as the last dilution in which quantification cycle (Cq) value could be detected in all replicates. The linear range correlation between the theoretical log copy number calculated from the concentration molarity of synthetic nucleic acids and Cq value was established applying a best-fit line to the data by linear regression analysis. PCR efficiency (E) was calculated from the slope of the linear equation.

    Search related documents:
    Co phrase search for related documents
    • linear regression analysis and low limit: 1, 2
    • linear regression analysis and nucleic acid: 1
    • linear regression analysis and quantification cycle: 1, 2
    • linear regression and LoD detection: 1, 2, 3, 4
    • LoD detection and low limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
    • LoD detection and nucleic acid: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50
    • LoD detection and PCR efficiency: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • LoD detection and quantification cycle: 1, 2
    • LoD detection and SARS sputum: 1, 2
    • LoD detection low limit and low limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
    • low limit and nucleic acid: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
    • low limit and PCR efficiency: 1
    • low limit and synthetic nucleic acid: 1
    • nasal exudate SARS sputum and SARS sputum: 1, 2
    • nucleic acid and PCR efficiency: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    • nucleic acid and quantification cycle: 1, 2, 3
    • nucleic acid and SARS sputum: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
    • nucleic acid and synthetic nucleic acid: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26
    • PCR efficiency and quantification cycle: 1