Selected article for: "antigen test and real time"

Author: Shah, M. M.; Salvatore, P. P.; Ford, L.; Kamitani, E.; Whaley, M. J.; Mitchell, K.; Currie, D. W.; Morgan, C. N.; Segaloff, H. E.; Lecher, S.; Somers, T.; Van Dyke, M. E.; Bigouette, J. P.; Delaney, A.; DaSilva, J.; O'Hegarty, M.; Boyle-Estheimer, L.; Abdirizak, F.; Karpathy, S. E.; Meece, J.; Ivanic, L.; Goffard, K.; Gieryn, D.; Sterkel, A.; Bateman, A.; Kahrs, J.; Langolf, K.; Zochert, T.; Knight, N. W.; Hsu, C. H.; Kirking, H. L.; Tate, J. E.
Title: Performance of Repeat BinaxNOW SARS-CoV-2 Antigen Testing in a Community Setting, Wisconsin, November-December 2020
  • Cord-id: u7xrm1iz
  • Document date: 2021_4_9
  • ID: u7xrm1iz
    Snippet: Repeating the BinaxNOW antigen test for SARS-CoV-2 by two groups of readers within 30 minutes resulted in high concordance (98.9%) in 2,110 encounters. BinaxNOW test sensitivity was 77.2% (258/334) compared to real-time reverse transcription-polymerase chain reaction. Same day antigen testing did not significantly improve test sensitivity while specificity remained high.
    Document: Repeating the BinaxNOW antigen test for SARS-CoV-2 by two groups of readers within 30 minutes resulted in high concordance (98.9%) in 2,110 encounters. BinaxNOW test sensitivity was 77.2% (258/334) compared to real-time reverse transcription-polymerase chain reaction. Same day antigen testing did not significantly improve test sensitivity while specificity remained high.