Selected article for: "establish protocol and real time"

Author: Zou, Jingbo; Zhi, Shenshen; Chen, Mengyuan; Su, Xingyu; Kang, Ling; Li, Caiyu; Su, Xiaosong; Zhang, Shiyin; Ge, Shengxiang; Li, Wei
Title: Heat inactivation decreases the Qualitative Real-time RT-PCR detection rates of clinical samples with high Cycle Threshold Values in COVID-19
  • Cord-id: ukah6hok
  • Document date: 2020_6_11
  • ID: ukah6hok
    Snippet: Abstract SARS-CoV-2 has caused COVID-19 pandemic globally in the beginning of 2020, and Qualitative Real-time RT-PCR has become the gold standard in diagnosis. As SARSCoV-2 with strong transmissibility and pathogenicity, it has become a professional consensus that clinical samples from suspected patients should be heat inactivated at 56°C for 30min before further processing. However, previous studies on the effect of inactivation on Qualitative Real-time RT-PCR were conducted with diluted sampl
    Document: Abstract SARS-CoV-2 has caused COVID-19 pandemic globally in the beginning of 2020, and Qualitative Real-time RT-PCR has become the gold standard in diagnosis. As SARSCoV-2 with strong transmissibility and pathogenicity, it has become a professional consensus that clinical samples from suspected patients should be heat inactivated at 56°C for 30min before further processing. However, previous studies on the effect of inactivation on Qualitative Real-time RT-PCR were conducted with diluted samples rather than clinical samples. The aim of this study was to investigate whether heatinactivation on clinical samples before detection will affect the accuracy of Qualitative Real-time RT-PCR detection. All 46 throat swab samples from 46 confirmed inpatients were detected by Qualitative Real-time RT-PCR directly, as well as after heat inactivation. Heat-Inactivation has significantly influenced the qualitative detection results on clinical samples, especially weakly positive samples. The results indicate the urgency to establish a more suitable protocol for COVID-19 clinical sample's inactivation.

    Search related documents:
    Co phrase search for related documents
    • abstract sars and acid detection: 1, 2, 3, 4
    • abstract sars and acid testing: 1
    • abstract sars and low concentration: 1
    • accurate diagnosis and acid detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • accurate diagnosis and acid testing: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    • accurate diagnosis and low concentration: 1, 2
    • acid detection and low concentration: 1, 2