Author: Kitagawa, Hiroki; Nomura, Toshihito; Nazmul, Tanuza; Kawano, Reo; Omori, Keitaro; Shigemoto, Norifumi; Sakaguchi, Takemasa; Ohge, Hiroki
Title: Effect of intermittent irradiation and fluence-response of 222 nm ultraviolet light on SARS-CoV-2 contamination Cord-id: rwo8hksl Document date: 2021_1_20
ID: rwo8hksl
Snippet: BACKGROUND: The effectiveness of 222 nm ultraviolet (UV) C light for disinfecting surfaces contaminated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been reported. The aim of this study was to evaluate the effect of the intermittent irradiation of 222 nm UVC on SARS-CoV-2 and the fluence-dependent effect of 222 nm UVC irradiation on SARS-CoV-2 inactivation. METHODS: We experimented with 5 min continuous and intermittent irradiation for 0.1, 0.05, 0.013, and 0.003 mW/cm(2
Document: BACKGROUND: The effectiveness of 222 nm ultraviolet (UV) C light for disinfecting surfaces contaminated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been reported. The aim of this study was to evaluate the effect of the intermittent irradiation of 222 nm UVC on SARS-CoV-2 and the fluence-dependent effect of 222 nm UVC irradiation on SARS-CoV-2 inactivation. METHODS: We experimented with 5 min continuous and intermittent irradiation for 0.1, 0.05, 0.013, and 0.003 mW/cm(2) of 222 nm UVC to evaluate the differences in the effect of the continuous and intermittent irradiation of 222 nm UVC on SARS-CoV-2 inactivation. For intermittent irradiation, we followed the on-off irradiation cycles with every 10-s irradiation followed by a 380-s interval. Thereafter, we evaluated the effects of 0.1, 0.013, and 0.003 mW/cm(2) 222 nm UVC irradiation on SARS-CoV-2 contamination at UV fluences of 1, 2, and 3 mJ/cm(2) at each irradiance. RESULTS: At each irradiance, no significant difference was observed in the log reduction of SARS-CoV-2 between continuous and intermittent irradiation. At each UV fluence, no significant difference was observed in the log reduction of SARS-CoV-2 among the three different irradiance levels. CONCLUSION: There was no significant difference between continuous and intermittent irradiation with 222 nm UVC with regards to SARS-CoV-2 inactivation. Moreover, 222 nm UVC inactivates SARS-CoV-2 in a fluence-dependent manner. The efficacy of 222-nm UVC irradiation in reducing the contamination of SARS-CoV-2 needs to be further evaluated in a real-world setting.
Search related documents:
Co phrase search for related documents, hyperlinks ordered by date