Selected article for: "acid nucleic and acute respiratory illness"

Author: Kim, Curi; Ahmed, Jamal A.; Eidex, Rachel B.; Nyoka, Raymond; Waiboci, Lilian W.; Erdman, Dean; Tepo, Adan; Mahamud, Abdirahman S.; Kabura, Wamburu; Nguhi, Margaret; Muthoka, Philip; Burton, Wagacha; Breiman, Robert F.; Njenga, M. Kariuki; Katz, Mark A.
Title: Comparison of Nasopharyngeal and Oropharyngeal Swabs for the Diagnosis of Eight Respiratory Viruses by Real-Time Reverse Transcription-PCR Assays
  • Cord-id: vd65ygtm
  • Document date: 2011_6_30
  • ID: vd65ygtm
    Snippet: BACKGROUND: Many acute respiratory illness surveillance systems collect and test nasopharyngeal (NP) and/or oropharyngeal (OP) swab specimens, yet there are few studies assessing the relative measures of performance for NP versus OP specimens. METHODS: We collected paired NP and OP swabs separately from pediatric and adult patients with influenza-like illness or severe acute respiratory illness at two respiratory surveillance sites in Kenya. The specimens were tested for eight respiratory viruse
    Document: BACKGROUND: Many acute respiratory illness surveillance systems collect and test nasopharyngeal (NP) and/or oropharyngeal (OP) swab specimens, yet there are few studies assessing the relative measures of performance for NP versus OP specimens. METHODS: We collected paired NP and OP swabs separately from pediatric and adult patients with influenza-like illness or severe acute respiratory illness at two respiratory surveillance sites in Kenya. The specimens were tested for eight respiratory viruses by real-time reverse transcription-polymerase chain reaction (qRT-PCR). Positivity for a specific virus was defined as detection of viral nucleic acid in either swab. RESULTS: Of 2,331 paired NP/OP specimens, 1,402 (60.1%) were positive for at least one virus, and 393 (16.9%) were positive for more than one virus. Overall, OP swabs were significantly more sensitive than NP swabs for adenovirus (72.4% vs. 57.6%, p<0.01) and 2009 pandemic influenza A (H1N1) virus (91.2% vs. 70.4%, p<0.01). NP specimens were more sensitive for influenza B virus (83.3% vs. 61.5%, p = 0.02), parainfluenza virus 2 (85.7%, vs. 39.3%, p<0.01), and parainfluenza virus 3 (83.9% vs. 67.4%, p<0.01). The two methods did not differ significantly for human metapneumovirus, influenza A (H3N2) virus, parainfluenza virus 1, or respiratory syncytial virus. CONCLUSIONS: The sensitivities were variable among the eight viruses tested; neither specimen was consistently more effective than the other. For respiratory disease surveillance programs using qRT-PCR that aim to maximize sensitivity for a large number of viruses, collecting combined NP and OP specimens would be the most effective approach.

    Search related documents:
    Co phrase search for related documents
    • acid extraction and adenovirus virus: 1, 2, 3, 4, 5, 6, 7, 8
    • acid extraction and low sensitivity: 1
    • acute respiratory illness and additional time: 1, 2
    • acute respiratory illness and adenovirus serotype: 1
    • acute respiratory illness and adenovirus virus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acute respiratory illness and low sensitivity: 1, 2, 3, 4
    • additional time and adenovirus virus: 1, 2
    • additional time and low sensitivity: 1, 2
    • adenovirus virus and low sensitivity: 1, 2, 3