Author: Mistry, Dylan A.; Wang, Jenny Y.; Moeser, Mika-Erik; Starkey, Thomas; Lee, Lennard Y. W.
Title: A systematic review of the sensitivity and specificity of lateral flow devices in the detection of SARS-CoV-2 Cord-id: r3hqpixr Document date: 2021_8_18
ID: r3hqpixr
Snippet: BACKGROUND: Lateral flow devices (LFDs) are viral antigen tests for the detection of SARS-CoV-2 that produce a rapid result, are inexpensive and easy to operate. They have been advocated for use by the World Health Organisation to help control outbreaks and break the chain of transmission of COVID-19 infections. There are now several studies assessing their accuracy but as yet no systematic review. Our aims were to assess the sensitivity and specificity of LFDs in a systematic review and summari
Document: BACKGROUND: Lateral flow devices (LFDs) are viral antigen tests for the detection of SARS-CoV-2 that produce a rapid result, are inexpensive and easy to operate. They have been advocated for use by the World Health Organisation to help control outbreaks and break the chain of transmission of COVID-19 infections. There are now several studies assessing their accuracy but as yet no systematic review. Our aims were to assess the sensitivity and specificity of LFDs in a systematic review and summarise the sensitivity and specificity of these tests. METHODS: A targeted search of Pubmed and Medxriv, using PRISMA principles, was conducted identifying clinical studies assessing the sensitivity and specificity of LFDs as their primary outcome compared to reverse transcriptase polymerase chain reaction (RT-PCR) for the detection of SARS-CoV-2. Based on extracted data sensitivity and specificity was calculated for each study. Data was pooled based on manufacturer of LFD and split based on operator (self-swab or by trained professional) and sensitivity and specificity data were calculated. RESULTS: Twenty-four papers were identified involving over 26,000 test results. Sensitivity from individual studies ranged from 37.7% (95% CI 30.6–45.5) to 99.2% (95% CI 95.5–99.9) and specificity from 92.4% (95% CI 87.5–95.5) to 100.0% (95% CI 99.7–100.0). Operation of the test by a trained professional or by the test subject with self-swabbing produced comparable results. CONCLUSIONS: This systematic review identified that the performance of lateral flow devices is heterogeneous and dependent on the manufacturer. Some perform with high specificity but a great range of sensitivities were shown (38.32–99.19%). Test performance does not appear dependent on the operator. Potentially, LFDs could support the scaling up of mass testing to aid track and trace methodology and break the chain of transmission of COVID-19 with the additional benefit of providing individuals with the results in a much shorter time frame. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12879-021-06528-3.
Search related documents:
Co phrase search for related documents- active infection and additional study: 1
- active infection and local government: 1, 2
- active infection and local national: 1, 2, 3
- active infection and low sensitivity: 1, 2, 3
- additional capacity and local government: 1
- additional capacity and local national: 1, 2
- additional capacity and low sensitivity: 1
- additional file and local national: 1
- additional study and local national: 1
- additional study and low sensitivity: 1
Co phrase search for related documents, hyperlinks ordered by date