Selected article for: "real time and time hand"

Author: T. Hans Derr; Melissa A. James; Chad V. Kuny; Prem P. Kandel; Matthew D. Beckman; Kevin L. Hockett; Mark A. Bates; Moriah L Szpara
Title: Aerosolized Hydrogen Peroxide Decontamination of N95 Respirators, with Fit-Testing and Virologic Confirmation of Suitability for Re-Use During the COVID-19 Pandemic
  • Document date: 2020_4_22
  • ID: d1crwbuz_12
    Snippet: For respirators subjected to repeated rounds of decontamination as part of this study, decontamination cycles were conducted repetitively from staging through drying. In order to be considered "dry" or ready for the next cycle, the interior and exterior respirator surfaces were monitored using a calibrated, hand-held ATI PortaSens II (real-time H2O2 monitor), and H2O2.....
    Document: For respirators subjected to repeated rounds of decontamination as part of this study, decontamination cycles were conducted repetitively from staging through drying. In order to be considered "dry" or ready for the next cycle, the interior and exterior respirator surfaces were monitored using a calibrated, hand-held ATI PortaSens II (real-time H2O2 monitor), and H2O2

    Search related documents: