Author: Sogade, Omolade O.; Aben, Rieta N.; Eyituoyo, Harry; Arinze, Nkechi C.; Sogade, Felix O.
Title: Feasibility study for echocardiographyâ€guided lead insertion for permanent cardiac implantable electronic devices Cord-id: r053jl83 Document date: 2021_7_18
ID: r053jl83
Snippet: BACKGROUND: Permanent cardiac implantable electronic devices (CIEDs) are traditionally implanted with the assistance of fluoroscopy. While clinically effective, this technique exposes both patients and providers to radiation which is associated with adverse health effects and represents an occupational hazard. In this study, we investigate the safety and feasibility of permanent CIED placement under the guidance of transthoracic echocardiography (TTE). There is also increasing interest in use of
Document: BACKGROUND: Permanent cardiac implantable electronic devices (CIEDs) are traditionally implanted with the assistance of fluoroscopy. While clinically effective, this technique exposes both patients and providers to radiation which is associated with adverse health effects and represents an occupational hazard. In this study, we investigate the safety and feasibility of permanent CIED placement under the guidance of transthoracic echocardiography (TTE). There is also increasing interest in use of nonâ€fluoroscopic options for noninvasive cardiac electrophysiologic procedures. METHODS: Fifteen patients consecutively consented for initial implant of CIEDs, specifically dual chamber pacemakers (DCPM) and dual chamber implantable cardioverter defibrillators (DCICDs). Patients were excluded if they had previous implants, abandoned leads, or anatomic anomalies including congenital and known persistent left superior vena cava (PLSVC). We used TTE to guide and implant atrial and ventricular leads. RESULTS: Eleven patients received DCPMs and four patients received DCICDs. The procedure duration was 49.3 min for DCICD and 52.3 min for DCPM, p = .807. The average number of right atrial lead attempts was 1.6 for DCPMs and 1.8 for DCICD, p = .860. The average number of right ventricular lead attempts for DCPMs was 2.2 and 1.0 attempt for DCICDs, p = .044. There were no complications at 90â€day followâ€up. CONCLUSION: We demonstrate the feasibility of TTEâ€guided DCPM/DCICD implantation without use of fluoroscopy. We present this method as a safe alternative for permanent CIED placement that may reduce risk of radiation exposure and cost while maintaining safety and efficacy. No operators wore lead aprons during the procedure.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date