Selected article for: "assay sensitivity and early time"

Author: Yassine, Hadi M.; Al-Jighefee, Hadeel; Al-Sadeq, Duaa W.; Dargham, Soha R.; Younes, Salma N.; Shurrab, Farah; Marei, Reham M.; Hssain, Ali Ait; Taleb, Sara; Alhussain, Hashim A.; Al-Nesf, Maryiam A.; Al-Khal, Abdullatif; Qotba, Hamda; Althani, Asmaa A.; Tang, Patrick; Abu-Raddad, Laith J.; Nasrallah, Gheyath K.
Title: Performance evaluation of five ELISA kits for detecting anti-SARS-COV-2 IgG antibodies
  • Cord-id: w0k9cqzz
  • Document date: 2020_10_27
  • ID: w0k9cqzz
    Snippet: OBJECTIVES: To evaluate and compare the performances of five commercial ELISA assays (EDI, AnshLabs, Dia.Pro, NovaTec, and Lionex) for detecting anti-SARS-CoV-2 IgG. METHODS: 70 negative control samples (collected before the COVID-19 pandemic) and samples from 101 RT-PCR-confirmed SARS-CoV-2 patients (collected at different time points from symptoms onset: ≤7, 8-14, and >14 days) were used to compare the sensitivity, specificity, agreement, positive and negative predictive values of each assay
    Document: OBJECTIVES: To evaluate and compare the performances of five commercial ELISA assays (EDI, AnshLabs, Dia.Pro, NovaTec, and Lionex) for detecting anti-SARS-CoV-2 IgG. METHODS: 70 negative control samples (collected before the COVID-19 pandemic) and samples from 101 RT-PCR-confirmed SARS-CoV-2 patients (collected at different time points from symptoms onset: ≤7, 8-14, and >14 days) were used to compare the sensitivity, specificity, agreement, positive and negative predictive values of each assay with RT-PCR. A concordance assessment between the five assays was also conducted. Cross-reactivity with other HCoV, non-HCoV respiratory viruses, non-respiratory viruses, and nuclear antigens was investigated. RESULTS: Lionex showed the highest specificity (98.6%, 95%CI: 92.3-99.8), followed by EDI and Dia.Pro (97.1%, 95%CI: 90.2-99.2), NovaTec (85.7%, 95%CI: 75.7-92.1), then AnshLabs (75.7%, 95%CI: 64.5-84.2). All ELISA kits cross-reacted with one anti-MERS IgG positive sample except Lionex. The sensitivity was low during the early stages of the disease but improved over time. After 14 days from symptoms onset, Lionex and NovaTec showed the highest sensitivity at 87.9% (95%CI: 72.7-95.2) and 86.4% (95%CI: 78.5-91.7), respectively. The agreement with RT-PCR results based on Cohen’s kappa was as follows: Lionex (0.89)> NovaTec (0.70)> Dia.Pro (0.69)> AnshLabs (0.63)> EDI (0.55). CONCLUSION: The Lionex ELISA, which measures antibodies solely to the S1 protein, demonstrated the best performance.

    Search related documents:
    Co phrase search for related documents
    • abbott architect and low sensitivity: 1, 2
    • acceptable specificity and low sensitivity: 1, 2, 3, 4, 5, 6
    • active infection and acute phase: 1, 2, 3, 4, 5, 6, 7
    • active infection and low respiratory: 1, 2, 3, 4
    • active infection and low respiratory tract: 1
    • active infection and low sensitivity: 1, 2, 3
    • acute phase and low respiratory: 1
    • acute phase and low sensitivity: 1, 2, 3, 4, 5, 6