Selected article for: "chain reaction and sensitivity analysis"

Author: Favresse, Julien; Cadrobbi, Julie; Eucher, Christine; Elsen, Marc; Laffineur, Kim; Dogné, Jean‐Michel; Douxfils, Jonathan
Title: Clinical performance of three fully automated anti‐SARS‐CoV‐2 immunoassays targeting the nucleocapsid or spike proteins
  • Cord-id: ugvwjnyo
  • Document date: 2020_12_1
  • ID: ugvwjnyo
    Snippet: This study assesses the clinical performance of three anti‐SARS‐CoV‐2 assays, namely EUROIMMUN anti‐SARS‐CoV‐2 nucleocapsid (IgG) ELISA, Elecsys anti‐SARS‐CoV‐2 nucleocapsid (total antibodies) assay, and LIAISON anti‐SARS‐CoV‐2 spike proteins S1 and S2 (IgG) assay. One hundred and thirty‐seven coronavirus disease 2019 (COVID‐19) samples from 96 reverse‐transcription polymerase chain reaction confirmed patients were chosen to perform the sensitivity analysis. Non‐S
    Document: This study assesses the clinical performance of three anti‐SARS‐CoV‐2 assays, namely EUROIMMUN anti‐SARS‐CoV‐2 nucleocapsid (IgG) ELISA, Elecsys anti‐SARS‐CoV‐2 nucleocapsid (total antibodies) assay, and LIAISON anti‐SARS‐CoV‐2 spike proteins S1 and S2 (IgG) assay. One hundred and thirty‐seven coronavirus disease 2019 (COVID‐19) samples from 96 reverse‐transcription polymerase chain reaction confirmed patients were chosen to perform the sensitivity analysis. Non‐SARS‐CoV‐2 sera (n = 141) with a potential cross‐reaction to SARS‐CoV‐2 immunoassays were included in the specificity analysis. None of these tests demonstrated a sufficiently high clinical sensitivity to diagnose acute infection. Fourteen days since symptom onset, we did not find any significant difference between the three techniques in terms of sensitivities. However, Elecsys performed better in terms of specificity. All three anti‐SARS‐CoV‐2 assays had equivalent sensitivities 14 days from symptom onset to diagnose past‐COVID‐19 infection. We also confirmed that anti‐SARS‐CoV‐2 determination before Day 14 is of less clinical interest.

    Search related documents:
    Co phrase search for related documents
    • acute infection and lob blank limit: 1
    • acute infection and lod detection: 1, 2, 3, 4
    • acute infection and low number: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • acute infection and low specificity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
    • additional method and lod detection: 1
    • lob blank limit and lod detection: 1, 2, 3, 4
    • lod detection and loq quantification: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
    • lod detection and loq quantification lod detection: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • lod detection and low number: 1, 2
    • lod detection and low specificity: 1, 2, 3
    • long term evolution and low number: 1