Author: Nallathambi, Gabriel; Rajbhandary, Paurakh; Tran, Thang; Colliou, Olivier
Title: Real-Time ECG Interval Monitoring Using a Fully Disposable Wireless Patch Sensor Cord-id: wwxz0uco Document date: 2021_8_1
ID: wwxz0uco
Snippet: ECG interval monitoring provides key insights into the diagnosis of cardiac diseases. The standard 12-lead ECG is generally used, however, because of the current COVID-19 pandemic there is a strong need for a remote monitoring solution which will reduce exposure of health care providers to coronavirus. This article presents a disposable wireless patch biosensor (VitalPatch) and associated platform functionalities for real-time continuous measurement of clinically relevant ECG intervals including
Document: ECG interval monitoring provides key insights into the diagnosis of cardiac diseases. The standard 12-lead ECG is generally used, however, because of the current COVID-19 pandemic there is a strong need for a remote monitoring solution which will reduce exposure of health care providers to coronavirus. This article presents a disposable wireless patch biosensor (VitalPatch) and associated platform functionalities for real-time continuous measurement of clinically relevant ECG intervals including PR interval, QRS duration, QT interval, corrected QT interval by Bazett (QTb), and corrected QT interval by Fridericia (QTf). The performance of the VitalPatch is validated by comparing its automated algorithm interval measurements to the manually annotated global intervals of the 12-lead ECG device in 30 subjects. The accuracy of interval monitoring (in terms of mean timing error calculated by subtracting the VitalPatch measurements from the global intervals) is 2.7+/-15.94 ms, -1.97+/-12.29 ms, -14.6+/-12.97 ms, - 15.33+/-14.11 ms, and -15.08+/-13.69 ms for PR interval, QRS duration, QT interval, QTb, and QTf, respectively. These results demonstrate that the VitalPatch is a viable solution for measuring ECG intervals while taking advantage of its remote monitoring feature during the pandemic.
Search related documents:
Co phrase search for related documents- abnormal normal and acute respiratory syndrome coronavirus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- abnormal normal and long term monitoring: 1, 2
- abnormality degree and acute respiratory syndrome: 1
- absence presence and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72
- absence presence and acute respiratory syndrome coronavirus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50
- absence presence and low energy: 1
- activity measure and acute respiratory syndrome: 1, 2, 3, 4, 5, 6
- activity measure and acute respiratory syndrome coronavirus: 1, 2, 3, 4, 5, 6
- acute respiratory syndrome and add benefit: 1, 2, 3
- acute respiratory syndrome and long term consequence: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- acute respiratory syndrome and long term monitoring: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
- acute respiratory syndrome and low energy: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
- acute respiratory syndrome coronavirus and add benefit: 1, 2
- acute respiratory syndrome coronavirus and long term consequence: 1, 2, 3, 4, 5
- acute respiratory syndrome coronavirus and long term monitoring: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
- acute respiratory syndrome coronavirus and low energy: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
Co phrase search for related documents, hyperlinks ordered by date