Selected article for: "analytical sensitivity and clinical sample"

Author: Jian, Ming-Jr; Chung, Hsing-Yi; Chang, Chih-Kai; Lin, Jung-Chung; Yeh, Kuo-Ming; Chen, Chien-Wen; Li, Shih-Yi; Hsieh, Shan-Shan; Liu, Ming-Tsan; Yang, Ji-Rong; Tang, Sheng-Hui; Perng, Cherng-Lih; Chang, Feng-Yee; Shang, Hung-Sheng
Title: Clinical Comparison of Three Sample-to-Answer Systems for Detecting SARS-CoV-2 in B.1.1.7 Lineage Emergence
  • Cord-id: xpbj7063
  • Document date: 2021_8_17
  • ID: xpbj7063
    Snippet: PURPOSE: Accurate molecular diagnostic assays for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of COVID-19, are needed for epidemiology studies and to support infection-control measures. We evaluated the analytical sensitivity and clinical performance of three sample-to-answer molecular-diagnostics systems for detecting SARS-CoV-2 using 325 nasopharyngeal swab clinical samples from symptomatic patients. METHODS: The BioFire Respiratory Panel 2.1 (RP
    Document: PURPOSE: Accurate molecular diagnostic assays for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of COVID-19, are needed for epidemiology studies and to support infection-control measures. We evaluated the analytical sensitivity and clinical performance of three sample-to-answer molecular-diagnostics systems for detecting SARS-CoV-2 using 325 nasopharyngeal swab clinical samples from symptomatic patients. METHODS: The BioFire Respiratory Panel 2.1 (RP2.1), cobas Liat SARS-CoV-2 and Influenza A/B, and Cepheid Xpert Xpress SARS-CoV-2/Flu/RSV platforms, which have been granted emergency-use authorization by the US FDA, were tested and compared. RESULTS: The positive percent agreement, negative percent agreement, and overall percent agreement among the three point of care testing systems were 98–100%, including for the wild-type SARS-CoV-2 (non-B.1.1.7) and a variant of concern (B.1.1.7). Notably, the BioFire RP2.1 may fail to detect the SARS-CoV-2 S gene in the B.1.1.7 lineage because of the spike protein mutation. CONCLUSION: All three point of care testing platforms provided highly sensitive, robust, and almost accurate results for rapidly detecting SARS-CoV-2. These automated molecular diagnostic assays can increase the effectiveness of control and prevention measures for infectious diseases.

    Search related documents:
    Co phrase search for related documents
    • absolute quantification and lod detection: 1, 2, 3
    • absolute quantification and lod detection limit: 1, 2, 3
    • accuracy performance and acid amplification: 1, 2
    • accuracy performance and lod detection: 1, 2
    • accuracy performance and lod detection limit: 1, 2
    • acid amplification and lod detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19
    • acid amplification and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
    • acid amplification test and lod detection: 1
    • acid amplification test and lod detection limit: 1