Author: Okada, Morihito; Miyata, Yoshihiro; Takamochi, Kazuya; Tsutani, Yasuhiro; Oh, Shiaki; Suzuki, Kenji
Title: Prospective feasibility study of sealing pulmonary vessels with energy in lung surgery. Cord-id: w6722mz8 Document date: 2019_1_1
ID: w6722mz8
Snippet: OBJECTIVE Vascular sealing with an energy vessel sealing system during lung resection may allow surgeons to treat small vessels with minimal dissection, possibly decreasing likelihood of injury. Few large prospective trials have examined the proximal sides of vessels not ligated in addition to sealing during surgery. We therefore assessed feasibility of an energy device to seal pulmonary artery and vein branches without further ligation. METHODS This prospective, preoperative registration study
Document: OBJECTIVE Vascular sealing with an energy vessel sealing system during lung resection may allow surgeons to treat small vessels with minimal dissection, possibly decreasing likelihood of injury. Few large prospective trials have examined the proximal sides of vessels not ligated in addition to sealing during surgery. We therefore assessed feasibility of an energy device to seal pulmonary artery and vein branches without further ligation. METHODS This prospective, preoperative registration study at 2 institutions evaluated safety of energy sealing with the LigaSure (Medtronic, Minneapolis, Minn), with no additional reinforcing material such as suture ligation, for pulmonary vessels as large as 7 mm during anatomic lung resection (cohort 1 study). A postoperative hemorrhage occurred in the 128th case, so a cohort 2 study proceeded after we changed inclusion criterion for pulmonary arteries from a maximum of 7 mm to a maximum of 5 mm. RESULTS In cohort 1 (n = 128) and cohort 2 (n = 200), 216 and 250 pulmonary arteries and 189 and 213 pulmonary veins, respectively, were treated with energy sealing. Overall postoperative hemorrhage rate was 0.3% (1/328 patients); however, no serious postoperative complications were associated with energy sealing among the 200 patients in cohort 2. Subsequent inspection of the torn artery stump confirmed that the bleeding in the 128th case was in an area adjacent to the sealing zone. CONCLUSIONS Energy sealing without reinforcement allows secure treatment during lung resection of pulmonary arteries as large as 5 mm in diameter and pulmonary veins as large as 7 mm.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date