Author: Kojima, N; Turner, F; Slepnev, V; Bacelar, A; Deming, L; Kodeboyina, S; Klausner, J D
                    Title: Self-Collected Oral Fluid and Nasal Swab Specimens Demonstrate Comparable Sensitivity to Clinician-Collected Nasopharyngeal Swab Specimens for the Detection of SARS-CoV-2  Cord-id: v6k9ifzi  Document date: 2020_10_19
                    ID: v6k9ifzi
                    
                    Snippet: We compared self-collected oral fluid swab specimens with and without clinician supervision, clinician-supervised self-collected mid-turbinate (nasal) swab specimens, and clinician-collected nasopharyngeal swab specimens for the detection of SARS-CoV-2. Supervised oral fluid and nasal swab specimens performed similarly to clinician-collected nasopharyngeal swab specimens. No sample type could detect SARS-CoV-2 infections amongst all positive participants.
                    
                    
                    
                     
                    
                    
                    
                    
                        
                            
                                Document: We compared self-collected oral fluid swab specimens with and without clinician supervision, clinician-supervised self-collected mid-turbinate (nasal) swab specimens, and clinician-collected nasopharyngeal swab specimens for the detection of SARS-CoV-2. Supervised oral fluid and nasal swab specimens performed similarly to clinician-collected nasopharyngeal swab specimens. No sample type could detect SARS-CoV-2 infections amongst all positive participants.
 