Author: Sampad, Mohammad Julker Neyen; Zhang, Han; Yuzvinsky, Thomas D.; Stott, Matthew A.; Hawkins, Aaron R.; Schmidt, Holger
                    Title: Optical trapping assisted label-free and amplification-free detection of SARS-CoV-2 RNAs with an optofluidic nanopore sensor  Cord-id: z7zfhhny  Document date: 2021_12_15
                    ID: z7zfhhny
                    
                    Snippet: Ultrasensitive, versatile sensors for molecular biomarkers are a critical component of disease diagnostics and personalized medicine as the COVID-19 pandemic has revealed in dramatic fashion. Integrated electrical nanopore sensors can fill this need via label-free, direct detection of individual biomolecules, but a fully functional device for clinical sample analysis has yet to be developed. Here, we report amplification-free detection of SARS-CoV-2 RNAs with single molecule sensitivity from cli
                    
                    
                    
                     
                    
                    
                    
                    
                        
                            
                                Document: Ultrasensitive, versatile sensors for molecular biomarkers are a critical component of disease diagnostics and personalized medicine as the COVID-19 pandemic has revealed in dramatic fashion. Integrated electrical nanopore sensors can fill this need via label-free, direct detection of individual biomolecules, but a fully functional device for clinical sample analysis has yet to be developed. Here, we report amplification-free detection of SARS-CoV-2 RNAs with single molecule sensitivity from clinical nasopharyngeal swab samples on an electro-optofluidic chip. The device relies on optically assisted delivery of target carrying microbeads to the nanopore for single RNA detection after release. A sensing rate enhancement of over 2,000x with favorable scaling towards lower concentrations is demonstrated. The combination of target specificity, chip-scale integration and rapid detection ensures the practicality of this approach for COVID-19 diagnosis over the entire clinically relevant concentration range from 10(4)-10(9) copies/mL.
 
  Search related documents: 
                                Co phrase  search for related documents- local concentration and low concentration: 1, 2, 3, 4
  - low detection and magnetic bead: 1, 2, 3
  
 
                                Co phrase  search for related documents, hyperlinks ordered by date