Author: Wang, Yong; Fu, Ziteng; Guo, Xu; Zhang, Da; Bai, Caixia; Li, Wei; Liu, Guangqing; Li, Yongdong; Jiang, Shudong
                    Title: Development of SYBR Green I-based Real-time Reverse Transcription Polymerase Chain Reaction for the Detection of Feline Astrovirus.  Cord-id: yi93qu1q  Document date: 2020_11_3
                    ID: yi93qu1q
                    
                    Snippet: In this study, a SYBR Green I-based real-time reverse transcription-polymerase chain reaction (RT-PCR) was developed for the clinical diagnosis of feline astroviruses (FeAstVs). Specific primers were designed based on the conserved region of the FeAstV ORF1b gene. Experiments for specificity, sensitivity, and repeatability of the assay were carried out. In addition, the assay was evaluated using clinical samples. Specificity analysis indicated that the assay showed negative results with samples 
                    
                    
                    
                     
                    
                    
                    
                    
                        
                            
                                Document: In this study, a SYBR Green I-based real-time reverse transcription-polymerase chain reaction (RT-PCR) was developed for the clinical diagnosis of feline astroviruses (FeAstVs). Specific primers were designed based on the conserved region of the FeAstV ORF1b gene. Experiments for specificity, sensitivity, and repeatability of the assay were carried out. In addition, the assay was evaluated using clinical samples. Specificity analysis indicated that the assay showed negative results with samples of Feline Parvovirus, Feline Herpesvirus, Feline Calicivirus, Feline Bocavirus, and Feline Coronavirus, indicating good specificity of the assay. Sensitivity analysis showed that the SYBR Green I-based real-time RT-PCR method could detect as low as 3.72 × 101 copies/μL of template, which is 100-fold more sensitive compared to the conventional RT-PCR. Both intra-assay and inter-assay variability were lower than 1%, indicating good reproducibility. Furthermore, an analysis of 150 fecal samples showed that the positive detection rate of SYBR Green I-based real-time RT-PCR was higher than that of the conventional RT-PCR, indicating the high reliability of the method. The assay is cheap and effective. Therefore, it could provide support for the detection of FeAstV in large-scale clinical testing and epidemiological investigation.
 
  Search related documents: 
                                Co phrase  search for related documents- Try single phrases listed below for: 1
 
                                Co phrase  search for related documents, hyperlinks ordered by date