Author: Chiumello, Davide; Busana, Mattia; Coppola, Silvia; Romitti, Federica; Formenti, Paolo; Bonifazi, Matteo; Pozzi, Tommaso; Palumbo, Maria Michela; Cressoni, Massimo; Herrmann, Peter; Meissner, Konrad; Quintel, Michael; Camporota, Luigi; Marini, John J.; Gattinoni, Luciano
Title: Physiological and quantitative CT-scan characterization of COVID-19 and typical ARDS: a matched cohort study Cord-id: xllvvq3l Document date: 2020_10_21
ID: xllvvq3l
Snippet: PURPOSE: To investigate whether COVID-19-ARDS differs from all-cause ARDS. METHODS: Thirty-two consecutive, mechanically ventilated COVID-19-ARDS patients were compared to two historical ARDS sub-populations 1:1 matched for PaO(2)/FiO(2) or for compliance of the respiratory system. Gas exchange, hemodynamics and respiratory mechanics were recorded at 5 and 15 cmH(2)O PEEP. CT scan variables were measured at 5 cmH(2)O PEEP. RESULTS: Anthropometric characteristics were similar in COVID-19-ARDS, Pa
Document: PURPOSE: To investigate whether COVID-19-ARDS differs from all-cause ARDS. METHODS: Thirty-two consecutive, mechanically ventilated COVID-19-ARDS patients were compared to two historical ARDS sub-populations 1:1 matched for PaO(2)/FiO(2) or for compliance of the respiratory system. Gas exchange, hemodynamics and respiratory mechanics were recorded at 5 and 15 cmH(2)O PEEP. CT scan variables were measured at 5 cmH(2)O PEEP. RESULTS: Anthropometric characteristics were similar in COVID-19-ARDS, PaO(2)/FiO(2)-matched-ARDS and Compliance-matched-ARDS. The PaO(2)/FiO(2)-matched-ARDS and COVID-19-ARDS populations (both with PaO(2)/FiO(2) 106 ± 59 mmHg) had different respiratory system compliances (Crs) (39 ± 11 vs 49.9 ± 15.4 ml/cmH(2)O, p = 0.03). The Compliance-matched-ARDS and COVID-19-ARDS had similar Crs (50.1 ± 15.7 and 49.9 ± 15.4 ml/cmH(2)O, respectively) but significantly lower PaO(2)/FiO(2) for the same Crs (160 ± 62 vs 106.5 ± 59.6 mmHg, p < 0.001). The three populations had similar lung weights but COVID-19-ARDS had significantly higher lung gas volume (PaO(2)/FiO(2)-matched-ARDS 930 ± 644 ml, COVID-19-ARDS 1670 ± 791 ml and Compliance-matched-ARDS 1301 ± 627 ml, p < 0.05). The venous admixture was significantly related to the non-aerated tissue in PaO(2)/FiO(2)-matched-ARDS and Compliance-matched-ARDS (p < 0.001) but unrelated in COVID-19-ARDS (p = 0.75), suggesting that hypoxemia was not only due to the extent of non-aerated tissue. Increasing PEEP from 5 to 15 cmH(2)O improved oxygenation in all groups. However, while lung mechanics and dead space improved in PaO(2)/FiO(2)-matched-ARDS, suggesting recruitment as primary mechanism, they remained unmodified or worsened in COVID-19-ARDS and Compliance-matched-ARDS, suggesting lower recruitment potential and/or blood flow redistribution. CONCLUSIONS: COVID-19-ARDS is a subset of ARDS characterized overall by higher compliance and lung gas volume for a given PaO(2)/FiO(2), at least when considered within the timeframe of our study. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00134-020-06281-2) contains supplementary material, which is available to authorized users.
Search related documents:
Co phrase search for related documents- absolute value and low baseline: 1
- absolute value and lung injury: 1, 2
- acute onset and lung injury: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18
- acute onset and lung injury etiology: 1
- acute respiratory distress syndrome and low baseline: 1, 2, 3
- acute respiratory distress syndrome and low ventilation perfusion: 1, 2
- acute respiratory distress syndrome and lung gas volume: 1, 2, 3, 4
- acute respiratory distress syndrome and lung injury: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acute respiratory distress syndrome and lung injury etiology: 1, 2
- low ventilation perfusion and lung injury: 1
Co phrase search for related documents, hyperlinks ordered by date