Author: Bier, C.; Edelmann, A.; Theil, K.; Schwarzer, R.; Deichner, M.; Gessner, A.; Hiergeist, A.; Rentschler, U.; Gohl, P.; Kuchta, A.; Manohar, C.; Santini, C.; Duncan, D.; Canchola, J.; Sun, J.; Spier, G.; Simon, C.
Title: Multi-site Evaluation of SARS-CoV-2 Spike Mutation Detection Using a Multiplex Real-time RT-PCR Assay Cord-id: vs462lri Document date: 2021_5_7
ID: vs462lri
Snippet: Background. SARS-CoV-2 causes COVID-19, which can be fatal and is responsible for a global pandemic. Variants with increased transmissibility or the potential to evade immunity have emerged and represent a threat to global pandemic control. Variants of concern (VOC) can be identified by sequencing of viral RNA, or by more rapid methods for detection of subsets of signature mutations. Methods. We developed a multiplex, real-time RT-PCR assay (cobas SARS-CoV-2 Variant Set 1) for the qualitative de
Document: Background. SARS-CoV-2 causes COVID-19, which can be fatal and is responsible for a global pandemic. Variants with increased transmissibility or the potential to evade immunity have emerged and represent a threat to global pandemic control. Variants of concern (VOC) can be identified by sequencing of viral RNA, or by more rapid methods for detection of subsets of signature mutations. Methods. We developed a multiplex, real-time RT-PCR assay (cobas SARS-CoV-2 Variant Set 1) for the qualitative detection and differentiation of three key SARS-CoV-2 mutations in the viral spike protein: del 69-70, E484K and N501Y. Analytical sensitivity and accuracy were evaluated at three testing sites using clinical specimens from patients infected with SARS-CoV-2 variants belonging to several different lineages, including B.1.1.7, B.1.351, and P.1. Results. The limit of detection for E484K was between 180 and 620 IU/mL for the three different isolates tested. For N501Y, the LOD was between 270 and 720 IU/mL (five isolates), while for del 69-70, it was 80 - 92 IU/mL (two isolates). Valid test results were obtained with all clinical specimens that were positive using routine diagnostic tests. Compared to sequencing (Sanger and next-generation), test results were 100% concordant at all three loci; no false positive or false negative results were observed. Conclusions. Data collected at three independent laboratories indicates excellent performance and concordance of cobas SARS-CoV-2 Variant Set 1 with sequencing. New sets of primers and probes that target additional loci can be rapidly deployed in response to the identification of other emerging variants.
Search related documents:
Co phrase search for related documents- absence presence and acid ribonucleic: 1, 2
- absence presence and lod detection: 1
- absence presence and lod detection limit: 1
- absence presence and low concentration: 1, 2, 3
- accuracy study and acid ribonucleic: 1
- accuracy study and lod detection: 1, 2, 3, 4
- accuracy study and lod detection limit: 1, 2, 3, 4
- accuracy study and low concentration: 1
- acid extraction and lod detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
- acid extraction and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
- acid extraction and low concentration: 1, 2, 3
- acid extraction and low concentration present: 1, 2
- acid ribonucleic and lod detection: 1, 2, 3
- acid ribonucleic and lod detection limit: 1, 2, 3
- lod detection and low concentration: 1, 2, 3, 4, 5, 6
- lod detection limit and low concentration: 1, 2, 3, 4, 5, 6
Co phrase search for related documents, hyperlinks ordered by date