Selected article for: "streptavidin immobilization and surface treatment"

Author: Kenneth N. Hass; Mengdi Bao; Qian He; Myeongkee Park; Peiwu Qin; Ke Du
Title: Integrated Micropillar Polydimethylsiloxane Accurate CRISPR Detection (IMPACT) System for Rapid Viral DNA Sensing
  • Document date: 2020_3_20
  • ID: d840uu3e_20
    Snippet: Streptavidin Immobilization: After surface treatment, each channel was injected with 20 µl of Streptavidin (ThermoFisher Scientific, Streptavidin S888) at a concentration of 4 mg/ml using a 23 GA microliter syringe (Hamilton). Since each channel has a volume of ~14 µl, any excess solution was allowed to exit to the outlet. The solution was left in the channel for 2 hrs to incubate......
    Document: Streptavidin Immobilization: After surface treatment, each channel was injected with 20 µl of Streptavidin (ThermoFisher Scientific, Streptavidin S888) at a concentration of 4 mg/ml using a 23 GA microliter syringe (Hamilton). Since each channel has a volume of ~14 µl, any excess solution was allowed to exit to the outlet. The solution was left in the channel for 2 hrs to incubate.

    Search related documents: