Selected article for: "low weight and lung disease"

Author: Singh, Bindya S; Gilbert, Urquidez; Singh, Sharad; Govindaswami, Balaji
Title: Sidestream microstream end tidal carbon dioxide measurements and blood gas correlations in neonatal intensive care unit.
  • Cord-id: vkrqyexz
  • Document date: 2013_1_1
  • ID: vkrqyexz
    Snippet: OBJECTIVE The study was designed to assess the use of newer sidestream microstream end tidal carbon dioxide (ETCO(2) ) device in predicting blood carbon dioxide (PCO(2) ) measurements in very low birth weight (VLBW = birth weight <1,500 g) and non-VLBW NICU neonates. STUDY DESIGN Sidestream microstream ETCO(2) detectors were allowed time to calibrate and reach steady state prior to blood gas measurements. Blood CO(2) (PCO(2) ) and simultaneous ETCO(2) were recorded. Ratio of dead space to tidal
    Document: OBJECTIVE The study was designed to assess the use of newer sidestream microstream end tidal carbon dioxide (ETCO(2) ) device in predicting blood carbon dioxide (PCO(2) ) measurements in very low birth weight (VLBW = birth weight <1,500 g) and non-VLBW NICU neonates. STUDY DESIGN Sidestream microstream ETCO(2) detectors were allowed time to calibrate and reach steady state prior to blood gas measurements. Blood CO(2) (PCO(2) ) and simultaneous ETCO(2) were recorded. Ratio of dead space to tidal volume (VD/VT) was calculated using modified Bohr's equation. Correlation coefficient, estimates of difference, standard deviation, and 95% limits of agreement between ETCO(2) and PCO(2) concentrations were calculated. RESULTS Two hundred eighty-six paired samples were collected from 48 ventilated NICU patients. Average PCO(2) and ETCO(2) were 58.4 and 50.6 with a correlation of 0.76. Subgroup analysis showed a correlation of 0.73 in 204 paired blood from 34 VLBW infants and 0.82 in 82 paired samples from non-VLBW infants. Estimates of difference ± standard deviation between PCO(2) and ETCO(2) concentrations in these three groups, respectively (ALL, VLBW, and non-VLBW) were 7.84 ± 9.96, 8.2 ± 10.16, and 6.95 ± 9.45. The correlation coefficient significantly improved in the VLBW group to 0.86 with dead space to tidal volume ratio (VD/VT) <30% (0.86 vs. 0.42; P < 0.001). CONCLUSION ETCO(2) measurements using sidestream microstream technology in VLBW demonstrated that the correlation of ETCO(2) and PCO(2) was moderate, but the agreement was less than adequate (bias > 5 mmHg in all groups). The results improved with lower VD/VT, suggesting that sidestream capnography is more reliable in conditions of less severe lung disease.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date