Author: Aljabo, Anas; Mueller, Eva; Abdul-Azeez, Dabeer; Hoare, Todd; Jain, Arun
Title: Gravity Steam Reprocessing in Healthcare Facilities for the Reuse of N95 Respirators Cord-id: w49cj2v3 Document date: 2020_10_2
ID: w49cj2v3
Snippet: BACKGROUND: COVID-19 has significantly impacted the health of millions of people around the world. The shortage of personal protective equipment, including N95 respirators, in hospital facilities has put frontline healthcare professionals at high risk for contracting this virus. AIM: To develop a reproducible and safe N95 respirator reprocessing method that satisfies all presented regulatory standards and can be directly implemented by hospitals using existing available equipment. METHODS: A non
Document: BACKGROUND: COVID-19 has significantly impacted the health of millions of people around the world. The shortage of personal protective equipment, including N95 respirators, in hospital facilities has put frontline healthcare professionals at high risk for contracting this virus. AIM: To develop a reproducible and safe N95 respirator reprocessing method that satisfies all presented regulatory standards and can be directly implemented by hospitals using existing available equipment. METHODS: A non-toxic gravity steam reprocessing method has been developed for the reuse of N95 respirators consisting of 30 minutes of steam treatment at 121°C followed by 30 minutes of heat drying. Samples of model number 1860, 1860s, 1870+, and 9105 N95 respirators were either collected from hospitals (for microbiology testing) or purchased new (for functionality testing), with all functionality tests (i.e. filter efficiency, fit evaluation, and strap integrity) performed at the Centers for Disease Control using standard procedures established by the National Institute for Occupational Safety and Health. FINDINGS: All tested models passed the minimum filter efficiency of 95% after three cycles of gravity steam reprocessing. The 1870+ N95 respirator model is the most promising model for reprocessing based on its efficient bacterial inactivation coupled with the maintenance of all other key functional respirator properties after multiple reprocessing steps. CONCLUSIONS: The gravity steam method can effectively reprocess N95 respirators over at least 3 reprocessing cycles without negatively impacting the functionality requirements set out by regulators. Enabling the reuse of N95 respirators is a crucial tool for managing both the current pandemic and future healthcare crises.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date