Selected article for: "absolute dose and low correlation"

Author: Tabatabaei, Seyed Mohammad Hossein; Talari, Hamidreza; Gholamrezanezhad, Ali; Farhood, Bagher; Rahimi, Habibollah; Razzaghi, Reza; Mehri, Narges; Rajebi, Hamid
Title: A low-dose chest CT protocol for the diagnosis of COVID-19 pneumonia: a prospective study
  • Cord-id: wnnltxlm
  • Document date: 2020_8_13
  • ID: wnnltxlm
    Snippet: PURPOSE: The increasing trend of chest CT utilization during the COVID-19 pandemic necessitates novel protocols with reduced dose and maintained diagnostic accuracy. We aimed to investigate the diagnostic accuracy of 30-mAs chest CT protocol in comparison with a 150-mAs standard-dose routine protocol for imaging of COVID-19 pneumonia. METHODS: Upon IRB approval, consecutive laboratory-confirmed positive COVID-19 patients aged 50 years or older who were referred for chest CT scan and had same-day
    Document: PURPOSE: The increasing trend of chest CT utilization during the COVID-19 pandemic necessitates novel protocols with reduced dose and maintained diagnostic accuracy. We aimed to investigate the diagnostic accuracy of 30-mAs chest CT protocol in comparison with a 150-mAs standard-dose routine protocol for imaging of COVID-19 pneumonia. METHODS: Upon IRB approval, consecutive laboratory-confirmed positive COVID-19 patients aged 50 years or older who were referred for chest CT scan and had same-day normal CXR were invited to participate in this prospective study. First, a standard-dose chest CT scan (150 mAs) was performed. Only if typical COVID-19 pneumonia features were identified, then a low-dose CT (30 mAs) was done immediately. Diagnostic accuracy of low-dose and standard-dose CT in the detection of typical COVID-19 pneumonia features were compared. RESULTS: Twenty patients with a mean age of 64.20 ± 13.8 were enrolled in the study. There was excellent intrareader agreement in detecting typical findings of COVID-19 pneumonia between low-dose and standard-dose (intraclass correlation coefficient [ICC] = 0.98–0.99, P values < 0.001 all readers). The mean effective dose values in standard- and low-dose groups were 6.60 ± 1.47 and 1.80 ± 0.42 mSv, respectively. Also, absolute cancer risk per mean cumulative effective dose values obtained from the standard- and low-dose CT examinations were 2.71 × 10(−4) and 0.74 × 10(−4), respectively. CONCLUSIONS: According to our study, it was found that proposed low-dose CT chest protocol is reliable in detecting COVID-19 pneumonia in daily practice with significant reduction in radiation dose and estimated cancer risk.

    Search related documents: