Selected article for: "diagnostic performance and present study"

Author: Younes, Salma; Al-Jighefee, Hadeel; Shurrab, Farah; Al-Sadeq, Duaa W.; Younes, Nadin; Dargham, Soha R.; Al-Dewik, Nader; Qotba, Hamda; Syed, Mohamed; Alnuaimi, Ahmed; Yassine, Hadi M.; Tang, Patrick; Abu-Raddad, Laith J.; Nasrallah, Gheyath K.
Title: Diagnostic Efficiency of Three Fully Automated Serology Assays and Their Correlation with a Novel Surrogate Virus Neutralization Test in Symptomatic and Asymptomatic SARS-COV-2 Individuals
  • Cord-id: zovdiv1x
  • Document date: 2021_1_25
  • ID: zovdiv1x
    Snippet: To support the deployment of serology assays for population screening during the COVID-19 pandemic, we compared the performance of three fully automated SARS-CoV-2 IgG assays: Mindray CL-900i(®) (target: spike [S] and nucleocapsid [N]), BioMérieux VIDAS(®)3 (target: receptor-binding domain [RBD]) and Diasorin LIAISON(®)XL (target: S1 and S2 subunits). A total of 111 SARS-CoV-2 RT-PCR- positive samples collected at ≥ 21 days post symptom onset, and 127 pre-pandemic control samples were incl
    Document: To support the deployment of serology assays for population screening during the COVID-19 pandemic, we compared the performance of three fully automated SARS-CoV-2 IgG assays: Mindray CL-900i(®) (target: spike [S] and nucleocapsid [N]), BioMérieux VIDAS(®)3 (target: receptor-binding domain [RBD]) and Diasorin LIAISON(®)XL (target: S1 and S2 subunits). A total of 111 SARS-CoV-2 RT-PCR- positive samples collected at ≥ 21 days post symptom onset, and 127 pre-pandemic control samples were included. Diagnostic performance was assessed in correlation to RT-PCR and a surrogate virus-neutralizing test (sVNT). Moreover, cross-reactivity with other viral antibodies was investigated. Compared to RT-PCR, LIAISON(®)XL showed the highest overall specificity (100%), followed by VIDAS(®)3 (98.4%) and CL-900i(®) (95.3%). The highest sensitivity was demonstrated by CL-900i(®) (90.1%), followed by VIDAS(®)3 (88.3%) and LIAISON(®)XL (85.6%). The sensitivity of all assays was higher in symptomatic patients (91.1–98.2%) compared to asymptomatic patients (78.4–80.4%). In correlation to sVNT, all assays showed excellent sensitivities (92.2–96.1%). In addition, VIDAS(®)3 demonstrated the best correlation (r = 0.75) with the sVNT. The present study provides insights on the performance of three fully automated assays, which could help diagnostic laboratories in the choice of a particular assay according to the intended use.

    Search related documents:
    Co phrase search for related documents
    • abbott architect and active infection: 1, 2
    • abbott architect and live virus: 1
    • abbott architect and low performance: 1
    • abbott architect and low sensitivity: 1, 2
    • absolute value and active infection: 1
    • absolute value and low performance: 1, 2
    • accurate determination and live virus: 1, 2
    • accurate evaluation and active infection: 1
    • accurate evaluation and active surveillance: 1, 2
    • accurate tool and low performance: 1, 2
    • accurate tool and low sensitivity: 1, 2, 3
    • active infection and live virus: 1
    • active infection and low performance: 1
    • active infection and low sensitivity: 1, 2, 3
    • active surveillance and live virus: 1, 2
    • active surveillance and low sensitivity: 1
    • live virus and low sensitivity: 1