Selected article for: "institutional animal care and vivo study"

Author: Omotosho, Philip; Yurcisin, Basil; Ceppa, Eugene; Miller, Jeffrey; Kirsch, David; Portenier, Dana D
Title: In vivo assessment of an absorbable and nonabsorbable knotless barbed suture for laparoscopic single-layer enterotomy closure: a clinical and biomechanical comparison against nonbarbed suture.
  • Cord-id: um9blevj
  • Document date: 2011_1_1
  • ID: um9blevj
    Snippet: BACKGROUND Laparoscopic intracorporeal suturing and knot tying is a complex skill that requires repeated deliberate practice to master. A novel self-anchoring barbed suture material that does not require knot tying can eliminate knot failure and reduce operating time. The goal of this study was to compare the in vivo efficacy of two novel knotless barbed sutures (absorbable and nonabsorbable) for use with the Endo Stitchâ„¢ device (Covidien), against conventional suture (Endo Stitch device with
    Document: BACKGROUND Laparoscopic intracorporeal suturing and knot tying is a complex skill that requires repeated deliberate practice to master. A novel self-anchoring barbed suture material that does not require knot tying can eliminate knot failure and reduce operating time. The goal of this study was to compare the in vivo efficacy of two novel knotless barbed sutures (absorbable and nonabsorbable) for use with the Endo Stitchâ„¢ device (Covidien), against conventional suture (Endo Stitch device with Polysorbâ„¢ suture; Covidien) for laparoscopic closure of viscerotomies in canine stomach, jejunum, and colon. METHODS Following Institutional Animal Care and Use Committee approval, 24 dogs underwent laparoscopic creation of 25-mm viscerotomies, three each in the stomach, jejunum, and colon. All viscerotomies were closed with the Endo Stitch device using the absorbable or nonabsorbable barbed suture or conventional suture. Closure time for each viscerotomy was recorded. Animals were survived for 3, 10, or 21 days, at which point the viscerotomies were burst-pressure tested. RESULTS The closure leak rate in this study with 216 total viscerotomy closures was 0%. There was no statistically significant difference in mean burst pressure between viscerotomies closed with barbed suture versus control suture at any of the survival intervals. Barbed suture with the Endo Stitch device was associated with statistically significantly faster closure times than the control suture with the Endo Stitch device (P<.05), resulting in a reduction in closure time between 35% and 42%. CONCLUSION This study reports the first use of barbed suture for the Endo Stitch device in laparoscopic gastrointestinal closure. The barbed suture for the Endo Stitch device is effective for laparoscopic single-layer gastrointestinal closure and is associated with a significantly reduced closure time.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date