Author: Cho, Chi Hyun; Lee, Chang Kyu; Nam, Myung-Hyun; Yoon, Soo-Young; Lim, Chae Seung; Cho, Yunjung; Kim, Young Kee
Title: Evaluation of the AdvanSureâ„¢ real-time RT-PCR compared with culture and Seeplex RV15 for simultaneous detection of respiratory viruses()()() Cord-id: zgvxl4h3 Document date: 2014_1_30
ID: zgvxl4h3
Snippet: Recently, AdvanSure™ kit based on multiplex real-time PCR was developed for simultaneous detection of 14 respiratory viruses (RVs). We compared the performance of AdvanSure with those of Seeplex® RV 15 ACE and culture by determining their sensitivities and specificities against a composite reference standard. Four hundred thirty-seven respiratory samples were tested by modified shell vial culture method, RV 15 ACE, and AdvanSure. One hundred fourteen samples (26.2%) out of 437 samples were po
Document: Recently, AdvanSure™ kit based on multiplex real-time PCR was developed for simultaneous detection of 14 respiratory viruses (RVs). We compared the performance of AdvanSure with those of Seeplex® RV 15 ACE and culture by determining their sensitivities and specificities against a composite reference standard. Four hundred thirty-seven respiratory samples were tested by modified shell vial culture method, RV 15 ACE, and AdvanSure. One hundred fourteen samples (26.2%) out of 437 samples were positive by culture, while additional 91 (20.8%) were positive by AdvanSure or RV15. One hundred twelve of 114 culture-positive samples were positive by AdvanSure except 2 samples (1 adenovirus, 1 respiratory syncytial virus [RSV]). Overall, the sensitivities of culture, RV15, and AdvanSure were 74.5%, 89.8%, and 95.1%, respectively. Sensitivities of culture, RV15, and AdvanSure for each virus tested were as follows: 91/100/96% for influenza A, 60/0/100% for influenza B, 63/95/97% for RSV, 69/81/89% for adenovirus, and 87/93/93% for parainfluenza virus. For viruses not covered by culture, sensitivities of RV15 and AdvanSure were as follows: 77/88% for rhinovirus, 100/100% for coronavirus OC43, 40/100% for coronavirus 229E/NL63, 13/100% for metapneumovirus, and 44/100% for bocavirus. The overall specificities of culture, RV15, and AdvanSure were 100/98.9/99.5%, respectively. Of 45 coinfected specimens, AdvanSure detected 41 specimens (91.1%) as coinfected, while RV15 detected 27 specimens (60.0%) as coinfected. AdvanSure assay demonstrated exquisite performance for the detection of RVs and will be a valuable tool for the management of RV infection.
Search related documents:
Co phrase search for related documents- accuracy workflow and acid extraction system: 1
- accuracy workflow and adenovirus rsv: 1
- accuracy workflow maximize and acid extraction: 1
- accuracy workflow maximize and acid extraction system: 1
- accuracy workflow maximize and adenovirus rsv: 1
- accurate rapid and acid amplification test: 1, 2, 3, 4, 5, 6
- accurate rapid and acid extraction: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- accurate rapid and acid extraction system: 1
- accurate rapid and low number: 1, 2
- accurate rapid and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- accurate rapid and luminex molecular diagnostics: 1
- accurate rapid and magnetic bead: 1, 2
- accurate rapid diagnostic method and low sensitivity: 1
- acid amplification test and low sensitivity: 1
- acid extraction and adenovirus rsv: 1, 2, 3, 4, 5
- acid extraction and low number: 1
- acid extraction and low sensitivity: 1
- acid extraction and magnetic bead: 1, 2, 3, 4, 5, 6, 7
- acid extraction system and adenovirus rsv: 1
Co phrase search for related documents, hyperlinks ordered by date