Selected article for: "cell culture supernatant and detection limit"

Author: Pastorino, Boris; Touret, Franck; Gilles, Magali; de Lamballerie, Xavier; Charrel, Remi N.
Title: Heat Inactivation of Different Types of SARS-CoV-2 Samples: What Protocols for Biosafety, Molecular Detection and Serological Diagnostics?
  • Cord-id: wvixyfsv
  • Document date: 2020_7_7
  • ID: wvixyfsv
    Snippet: Standard precautions to minimize the risk of SARS-CoV-2 transmission implies that infected cell cultures and clinical specimens may undergo some sort of inactivation to reduce or abolish infectivity. We evaluated three heat inactivation protocols (56 °C-30 min, 60 °C-60 min and 92 °C-15 min) on SARS-CoV-2 using (i) infected cell culture supernatant, (ii) virus-spiked human sera (iii) and nasopharyngeal samples according to the recommendations of the European norm NF EN 14476-A2. Regardless of
    Document: Standard precautions to minimize the risk of SARS-CoV-2 transmission implies that infected cell cultures and clinical specimens may undergo some sort of inactivation to reduce or abolish infectivity. We evaluated three heat inactivation protocols (56 °C-30 min, 60 °C-60 min and 92 °C-15 min) on SARS-CoV-2 using (i) infected cell culture supernatant, (ii) virus-spiked human sera (iii) and nasopharyngeal samples according to the recommendations of the European norm NF EN 14476-A2. Regardless of the protocol and the type of samples, a 4 Log(10) TCID50 reduction was observed. However, samples containing viral loads > 6 Log(10) TCID(50) were still infectious after 56 °C-30 min and 60 °C-60 min, although infectivity was < 10 TCID(50). The protocols 56 °C-30 min and 60 °C-60 min had little influence on the RNA copies detection, whereas 92 °C-15 min drastically reduced the limit of detection, which suggests that this protocol should be avoided for inactivation ahead of molecular diagnostics. Lastly, 56 °C-30 min treatment of serum specimens had a negligible influence on the results of IgG detection using a commercial ELISA test, whereas a drastic decrease in neutralizing titers was observed.

    Search related documents:
    Co phrase search for related documents
    • acid extraction and lod detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
    • acid extraction and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
    • additional study and low impact: 1
    • load reduction and log 10 reduction: 1, 2, 3, 4, 5, 6
    • load reduction and low impact: 1
    • lod detection and low impact: 1
    • lod detection limit and low impact: 1