Selected article for: "cause mortality and multicenter study"

Author: Zeller, Thomas; Beschorner, Ulrich; Pilger, Ernst; Bosiers, Marc; Deloose, Koen; Peeters, Patrick; Scheinert, Dierk; Schulte, Karl-Ludwig; Rastan, Aljoscha; Brodmann, Marianne
Title: Paclitaxel-Coated Balloon in Infrapopliteal Arteries: 12-Month Results From the BIOLUX P-II Randomized Trial (BIOTRONIK'S-First in Man study of the Passeo-18 LUX drug releasing PTA Balloon Catheter vs. the uncoated Passeo-18 PTA balloon catheter in subjects requiring revascularization of infrapoplit
  • Cord-id: 3alr7xtx
  • Document date: 2015_1_1
  • ID: 3alr7xtx
    Snippet: OBJECTIVES The aim of BIOLUX P-II (BIOTRONIK'S-First in Man study of the Passeo-18 LUX drug releasing PTA Balloon Catheter vs. the uncoated Passeo-18 PTA balloon catheter in subjects requiring revascularization of infrapopliteal arteries) trial was to compare the safety and efficacy of a novel paclitaxel-coated drug-eluting balloon (DEB) versus an uncoated balloon (percutaneous transluminal angioplasty [PTA]) in de novo or native restenotic lesions of the infrapopliteal arteries in patients with
    Document: OBJECTIVES The aim of BIOLUX P-II (BIOTRONIK'S-First in Man study of the Passeo-18 LUX drug releasing PTA Balloon Catheter vs. the uncoated Passeo-18 PTA balloon catheter in subjects requiring revascularization of infrapopliteal arteries) trial was to compare the safety and efficacy of a novel paclitaxel-coated drug-eluting balloon (DEB) versus an uncoated balloon (percutaneous transluminal angioplasty [PTA]) in de novo or native restenotic lesions of the infrapopliteal arteries in patients with claudication and critical limb ischemia. BACKGROUND DEB have shown promising results in femoropopliteal lesions, but data for infrapopliteal lesions are scarce. METHODS In this prospective, multicenter, randomized first-in-man study, 72 patients were randomized 1:1 to either a Passeo-18 Lux DEB (Biotronik AG, Buelach, Switzerland) (n = 36) or Passeo-18 PTA (n = 36). Follow-up assessments were scheduled at 1, 6, and 12 months, with angiographic assessment at 6 months. Adverse events were adjudicated by an independent clinical events committee, and angiographic parameters were assessed by an independent core laboratory. RESULTS The primary safety endpoint (a composite of all-cause mortality, target extremity major amputation, target lesion thrombosis, and target vessel revascularization at 30 days) was 0% in the DEB group versus 8.3% in the PTA group (p = 0.239). The primary performance endpoint (patency loss at 6 months) was 17.1% in the DEB group versus 26.1% in the PTA group (p = 0.298), and major amputations of the target extremity occurred in 3.3% versus 5.6% of the patients at 12 months, respectively. CONCLUSIONS The Passeo-18 Lux DEB has been proven to be safe and effective in infrapopliteal lesions with comparable outcomes to PTA.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date