Selected article for: "general population and healthcare worker"

Author: Davies, Bethan; Araghi, Marzieh; Moshe, Maya; Gao, He; Bennet, Kimberly; Jenkins, Jordan; Atchison, Christina; Darzi, Ara; Ashby, Deborah; Riley, Steven; Barclay, Wendy; Elliott, Paul; Ward, Helen; Cooke, Graham
Title: Acceptability, usability and performance of lateral flow immunoassay tests for SARS-CoV-2 antibodies: REACT-2 study of self-testing in non-healthcare key workers
  • Cord-id: 5b279qb8
  • Document date: 2021_10_4
  • ID: 5b279qb8
    Snippet: BACKGROUND: Seroprevalence studies are essential to understand the epidemiology of SARS-CoV-2. Various technologies, including laboratory assays and point-of-care self-tests, are available for antibody testing. The interpretation of seroprevalence studies requires comparative data on the performance of antibody tests. METHODS: In June 2020, current and former members of the UK Police forces and Fire service performed a self-test lateral flow immunoassay (LFIA), had a nurse-performed LFIA and pro
    Document: BACKGROUND: Seroprevalence studies are essential to understand the epidemiology of SARS-CoV-2. Various technologies, including laboratory assays and point-of-care self-tests, are available for antibody testing. The interpretation of seroprevalence studies requires comparative data on the performance of antibody tests. METHODS: In June 2020, current and former members of the UK Police forces and Fire service performed a self-test lateral flow immunoassay (LFIA), had a nurse-performed LFIA and provided a venous blood sample for ELISA . We present the prevalence of antibodies to SARS-CoV-2; the acceptability and usability of self-test LFIAs; and determine the sensitivity and specificity of LFIAs compared to laboratory ELISA. RESULTS: In this cohort of 5189 current and former members of the Police service and 263 members of the Fire service, 7.4% (396/5,348; 95% CI, 6.7-8.1) were antibody positive. Seroprevalence was 8.9% (6.9-11.4) in those under 40 years, 11.5% (8.8-15.0) in those of non-white ethnicity and 7.8% (7.1-8.7) in those currently working. Self-test LFIA had an acceptability of 97.7% and a usability of 90.0%. There was substantial agreement between within-participant LFIA results (kappa 0.80; 0.77-0.83). The LFIAs had a similar performance: compared to ELISA, sensitivity was 82.1% (77.7-86.0) self-test and 76.4% (71.9-80.5) nurse-performed with specificity of 97.8% (97.3-98.2) and 98.5% (98.1-98.8) respectively. CONCLUSION: A greater proportion of this non-healthcare key worker cohort showed evidence of previous infection with SARS-CoV-2 than the general population at 6.0% (5.8-6.1) following the first wave in England. The high acceptability and usability reported by participants and similar performance of self-test and nurse-performed LFIAs indicate that the self-test LFIA is fit for purpose for home-testing in occupational and community prevalence studies.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date