Author: T. Hans Derr; Melissa A. James; Chad V. Kuny; Prem P. Kandel; Matthew D. Beckman; Kevin L. Hockett; Mark A. Bates; Moriah L Szpara
Title: Aerosolized Hydrogen Peroxide Decontamination of N95 Respirators, with Fit-Testing and Virologic Confirmation of Suitability for Re-Use During the COVID-19 Pandemic Document date: 2020_4_22
ID: d1crwbuz_32
Snippet: were qualitatively fit-tested (QLFT) using Occupational Safety and Health Administration (OSHA) fit test protocols (see Methods for details) (12) . We also carried out quantitative fittesting (QNFT) using OSHA protocol requirements. QNFT employs condensation nuclei counting technology to measure aerosol concentrations outside and inside the facepiece to determine a user fit-factor. Five new respirators of each facepiece were subjected to QLFT, fo.....
Document: were qualitatively fit-tested (QLFT) using Occupational Safety and Health Administration (OSHA) fit test protocols (see Methods for details) (12) . We also carried out quantitative fittesting (QNFT) using OSHA protocol requirements. QNFT employs condensation nuclei counting technology to measure aerosol concentrations outside and inside the facepiece to determine a user fit-factor. Five new respirators of each facepiece were subjected to QLFT, followed by QNFT. Successful QLFT and QNFT results were achieved for all five models of N-95 respirator facepieces shown in Table 1 .
Search related documents:
Co phrase search for related documents- aerosol concentration and facepiece inside outside aerosol concentration measure: 1
- aerosol concentration and fit factor: 1, 2
- aerosol concentration and fit test: 1
- aerosol concentration and fit test protocol: 1
- aerosol concentration and OSHA Health Occupational Safety Administration: 1
- aerosol concentration and OSHA protocol: 1
- aerosol concentration and respirator facepiece: 1
- aerosol concentration measure and condensation nucleus: 1
- aerosol concentration measure and facepiece inside outside aerosol concentration measure: 1
- aerosol concentration measure and fit factor: 1
- aerosol concentration measure and fit test: 1
- aerosol concentration measure and fit test protocol: 1
- aerosol concentration measure and OSHA Health Occupational Safety Administration: 1
- aerosol concentration measure and OSHA protocol: 1
- condensation nucleus and facepiece inside outside aerosol concentration measure: 1
- condensation nucleus and fit factor: 1
- condensation nucleus and fit test: 1
- condensation nucleus and OSHA Health Occupational Safety Administration: 1
- condensation nucleus and OSHA protocol: 1
Co phrase search for related documents, hyperlinks ordered by date