Author: Patrick Hunziker; Urs Zenklusen
Title: Ad-hoc Assembly of Lean Extracorporeal Membrane Oxygenation Systems for COVID-19 Document date: 2020_4_17
ID: 41v5shpt_32
Snippet: the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Figure 1 : Ad-hoc ECMO. A: Basic connectivity of ad hoc ECMO composed from Impella pumps and standard oxygenators. B, C: pieces and assembly of Impella CP-based ECMO system. D,E: pieces and assembly of Impella 5.0-based ad-hoc ECMO system. F: closed-loop setup for pump testing, was run for 48 hours and showed stable performance. G: venous access cannulas; .....
Document: the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Figure 1 : Ad-hoc ECMO. A: Basic connectivity of ad hoc ECMO composed from Impella pumps and standard oxygenators. B, C: pieces and assembly of Impella CP-based ECMO system. D,E: pieces and assembly of Impella 5.0-based ad-hoc ECMO system. F: closed-loop setup for pump testing, was run for 48 hours and showed stable performance. G: venous access cannulas; the 25F and 22F cannula were used in F. F: closed loop system including Impella pump, venous drainage and return cannulas, oxigenator module; to simulate oxygen extraction by a patient, an additional gas exchange module (flused with N2) is added. 48 hourtesting of this setup with reconstituted blood showed stable flows, and stable gas exchange. Impella CP, level 9
Search related documents:
Co phrase search for related documents- ad hoc ECMO system and gas exchange: 1, 2
- ad hoc ECMO system and gas exchange module: 1
- ad hoc ECMO system and Impella ad hoc ECMO system: 1
- ad hoc ECMO system and Impella pump: 1
- closed loop and gas exchange: 1, 2, 3, 4, 5
- closed loop and gas exchange module: 1
- closed loop and Impella pump: 1, 2
- closed loop and loop system: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- closed loop and oxygen extraction: 1
- closed loop and oxygen extraction simulate: 1
- closed loop setup and gas exchange: 1
- closed loop setup and gas exchange module: 1
- closed loop setup and Impella pump: 1
- closed loop setup and oxygen extraction: 1
- closed loop setup and oxygen extraction simulate: 1
- ECMO system and gas exchange: 1, 2, 3
- ECMO system and gas exchange module: 1
- ECMO system and Impella ad hoc ECMO system: 1
- ECMO system and Impella pump: 1
Co phrase search for related documents, hyperlinks ordered by date