Author: Chang, Ying-Feng; Wang, Sheng-Fan; Huang, Jason C.; Su, Li-Chen; Yao, Ling; Li, Ying-Chang; Wu, Suh-Chin; Chen, Yi-Ming A.; Hsieh, Jo-Ping; Chou, Chien
Title: Detection of swine-origin influenza A (H1N1) viruses using a localized surface plasmon coupled fluorescence fiber-optic biosensor Cord-id: no8awjfr Document date: 2010_11_15
ID: no8awjfr
Snippet: Swine-origin influenza A (H1N1) virus (S-OIV) was identified as a new reassortant strain of influenza A virus in April 2009 and led to an influenza pandemic. Accurate and timely diagnoses are crucial for the control of influenza disease. We developed a localized surface plasmon coupled fluorescence fiber-optic biosensor (LSPCF-FOB) which combines a sandwich immunoassay with the LSP technique using antibodies against the hemagglutinin (HA) proteins of S-OIVs. The detection limit of the LSPCF-FOB
Document: Swine-origin influenza A (H1N1) virus (S-OIV) was identified as a new reassortant strain of influenza A virus in April 2009 and led to an influenza pandemic. Accurate and timely diagnoses are crucial for the control of influenza disease. We developed a localized surface plasmon coupled fluorescence fiber-optic biosensor (LSPCF-FOB) which combines a sandwich immunoassay with the LSP technique using antibodies against the hemagglutinin (HA) proteins of S-OIVs. The detection limit of the LSPCF-FOB for recombinant S-OIV H1 protein detection was estimated at 13.9 pg/mL, which is 10(3)-fold better than that of conventional capture ELISA when using the same capture antibodies. For clinical S-OIV isolates measurement, meanwhile, the detection limit of the LSPCF-FOB platform was calculated to be 8.25 × 10(4) copies/mL, compared with 2.06 × 10(6) copies/mL using conventional capture ELISA. Furthermore, in comparison with the influenza A/B rapid test, the detection limit of the LSPCF-FOB for S-OIV was almost 50-fold in PBS solution and 25-fold lower in mimic solution, which used nasal mucosa from healthy donors as the diluent. The findings of this study therefore indicate that the high detection sensitivity and specificity of the LSPCF-FOB make it a potentially effective diagnostic tool for clinical S-OIV infection and this technique has the potential to be applied to the development of other clinical microbe detection platforms.
Search related documents:
Co phrase search for related documents- accurate convenient and acute respiratory syndrome: 1, 2, 3
- accurate convenient and low detection: 1, 2
- accurate convenient assay and acute respiratory syndrome: 1
- accurate rapid and acid detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- accurate rapid and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- accurate rapid and low detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- accurate rapid and low detection limit: 1, 2, 3, 4, 5
- accurate rapid and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- accurate rapid diagnostic method and acute respiratory syndrome: 1
- accurate rapid diagnostic method and low sensitivity: 1
- acid detection and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acid detection and low detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acid detection and low detection limit: 1, 2, 3, 4
- acid detection and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
- acute respiratory syndrome and low detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acute respiratory syndrome and low detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9
- acute respiratory syndrome and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
Co phrase search for related documents, hyperlinks ordered by date