Author: Minfeng Liao; Yang Liu; Jin Yuan; Yanling Wen; Gang Xu; Juanjuan Zhao; Lin Chen; Jinxiu Li; Xin Wang; Fuxiang Wang; Lei Liu; Shuye Zhang; Zheng Zhang
Title: The landscape of lung bronchoalveolar immune cells in COVID-19 revealed by single-cell RNA sequencing Document date: 2020_2_26
ID: 8l1vfsbc_40
Snippet: The throat swab, sputum, nasal swab and BALF were collected from the respiratory tract of the patients at various time-points after hospitalization. Viral RNAs were extracted by Viral RNA was extracted from samples using the QIAamp RNA Viral Kit (Qiagen, Heiden, Germany). Then quantitative reverse transcription polymerase chain reaction (qRT-PCR) was performed using the primers and probes targeting ORF1ab and N genes of SARS-CoV-2 recommended by .....
Document: The throat swab, sputum, nasal swab and BALF were collected from the respiratory tract of the patients at various time-points after hospitalization. Viral RNAs were extracted by Viral RNA was extracted from samples using the QIAamp RNA Viral Kit (Qiagen, Heiden, Germany). Then quantitative reverse transcription polymerase chain reaction (qRT-PCR) was performed using the primers and probes targeting ORF1ab and N genes of SARS-CoV-2 recommended by China CDC, and a commercial kit specific for SARS-CoV-2 detection (GeneoDX Co., Ltd., Shanghai, China). The specimens were considered tentatively positive if qRT-PCR Ct value lower than 37 is detected at any time-points during the hospitalization. Then the assay is repeated to confirm the positivity if the Ct value was similar or between 37~40. If the repeat Ct was above 40, then the specimen was considered negative.
Search related documents:
Co phrase search for related documents- chain reaction and Ct repeat: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
- chain reaction and Ct value: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- chain reaction and Heiden Qiagen QIAamp RNA viral kit: 1, 2
- chain reaction and low value: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- chain reaction and negative consider: 1
- chain reaction and patient respiratory tract: 1, 2, 3, 4, 5, 6
- chain reaction and PCR Ct low value: 1, 2, 3
- chain reaction and positivity confirm: 1, 2
- chain reaction and probe primer: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- chain reaction and QIAamp RNA viral kit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
- commercial kit and Ct repeat: 1
- commercial kit and Ct value: 1
- commercial kit and Heiden Qiagen QIAamp RNA viral kit: 1, 2
- commercial kit and probe primer: 1
- commercial kit and QIAamp RNA viral kit: 1, 2, 3
- Ct repeat and Ct value: 1, 2, 3, 4
- Ct repeat and Heiden Qiagen QIAamp RNA viral kit: 1
- Ct repeat and QIAamp RNA viral kit: 1
- Ct value and Heiden Qiagen QIAamp RNA viral kit: 1
Co phrase search for related documents, hyperlinks ordered by date