Author: Rinehart, Joseph; Lee, Christine; Cannesson, Maxime; Dumont, Guy
Title: Closed-loop fluid resuscitation: robustness against weight and cardiac contractility variations.
  • Cord-id: t4r68lvx
  • Document date: 2013_1_1
  • ID: t4r68lvx
    Snippet: BACKGROUND Surgical patients present with a wide variety of body sizes and blood volumes, have large differences in baseline volume status, and may exhibit significant differences in cardiac function. Any closed-loop fluid administration system must be robust against these differences. In the current study, we tested the stability and robustness of the closed-loop fluid administration system against the confounders of body size, starting volume status, and cardiac contractility using control eng
    Document: BACKGROUND Surgical patients present with a wide variety of body sizes and blood volumes, have large differences in baseline volume status, and may exhibit significant differences in cardiac function. Any closed-loop fluid administration system must be robust against these differences. In the current study, we tested the stability and robustness of the closed-loop fluid administration system against the confounders of body size, starting volume status, and cardiac contractility using control engineering methodology. METHODS Using an independently developed previously published hemodynamic simulation model that includes blood volumes and cardiac contractility, we ran a Monte-Carlo simulation series with variation in starting blood volume and body weight (phase 1, weight 35-100 kg), and starting blood volume and cardiac contractility (phase 2, contractility from 1500 [severe heart failure] to 6000 [hyperdynamic]). The performance of the controller in resuscitating to the target set point was evaluated in terms of milliliters of blood volume error from optimal, with <250 mL of error defined as "successful." RESULTS One thousand simulations were run for each of the 2 phases of the study. The phase 1 mean blood volume error ± SD from optimal was 25 ± 59 mL. The phase 2 mean blood volume error from optimal was -60 ± 89 mL. The lower 95% Clopper-Pearson binomial confidence interval for resuscitation to within 250 mL of optimal blood volume for phase 1 and 2 was 99.6% and 97.1%, respectively. CONCLUSION The results indicate that the controller is highly effective in targeting optimal blood and stroke volumes, regardless of weight, contractility or starting blood volume.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date