Selected article for: "flow rate and Îm size"

Author: Lobo-Júnior, Eulício O; Chagas, Cyro L S; Duarte, Lucas C; Cardoso, Thiago M G; de Souza, Fabrício R; Lima, Renato S; Coltro, Wendell K T
Title: Inexpensive and non-conventional fabrication of microfluidic devices in PMMA based on a soft-embossing protocol.
  • Cord-id: tiixqu1a
  • Document date: 2020_7_29
  • ID: tiixqu1a
    Snippet: This study describes an inexpensive and non-conventional soft-embossing protocol to produce microfluidic devices in PMMA. The desirable microfluidic structure was photo-patterned in a poly(vinyl acetate) (PVAc) film deposited on glass substrate to produce a low-relief master. Then, this template was used to generate a high-relief pattern in stiffened PDMS (S-PDMS) by increasing of curing agent /monomer ratio (1:5) followed by thermal aging in a laboratory oven (200°C for 24 h). The S-PDMS maste
    Document: This study describes an inexpensive and non-conventional soft-embossing protocol to produce microfluidic devices in PMMA. The desirable microfluidic structure was photo-patterned in a poly(vinyl acetate) (PVAc) film deposited on glass substrate to produce a low-relief master. Then, this template was used to generate a high-relief pattern in stiffened PDMS (S-PDMS) by increasing of curing agent /monomer ratio (1:5) followed by thermal aging in a laboratory oven (200°C for 24 h). The S-PDMS masters were used to replicate microfluidic devices in PMMA based on soft embossing at 220-230°C and thermal sealing at 140°C. Both embossing and sealing stages were performed by using binder clips. The proposed protocol has ensured the replication of microfluidic devices in PMMA with great fidelity (> 94%). Examples of ME devices, droplet generator devices and spot test array were successfully demonstrated. For testing ME devices, a mixture containing inorganic cations was selected as model and the achieved analytical performance did not reveal significant difference from commercial PMMA devices. Water droplets were successfully generated in an oil phase at rate of ca. 60 droplets/min (fixing the continuous phase flow rate at 100 μL/h) with size of ca. 322 ± 6 μm. Glucose colorimetric assay was performed on spot test devices and good detectability level was achieved. The obtained results for two artificial serum samples revealed good agreement with the certified concentrations. Based on the fabrication simplicity and great analytical performance, the proposed soft-embossing protocol may emerge as promising approach for manufacturing PMMA devices. This article is protected by copyright. All rights reserved.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date