Author: Wang, Qiang; Du, Qin; Guo, Bin; Mu, Daiyong; Lu, Xiaolan; Ma, Qiang; Guo, Yangliu; Fang, Li; Zhang, Bing; Zhang, Guoyuan; Guo, Xiaolan
Title: A Method To Prevent SARS-CoV-2 IgM False Positives in Gold Immunochromatography and Enzyme-Linked Immunosorbent Assays Cord-id: uge5uodk Document date: 2020_5_26
ID: uge5uodk
Snippet: We set out to investigate the interference factors that led to false-positive novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgM detection results using gold immunochromatography assay (GICA) and enzyme-linked immunosorbent assay (ELISA) and the corresponding solutions. GICA and ELISA were used to detect SARS-CoV-2 IgM in 86 serum samples, including 5 influenza A virus (Flu A) IgM-positive sera, 5 influenza B virus (Flu B) IgM-positive sera, 5 Mycoplasma pneumoniae IgM-positi
Document: We set out to investigate the interference factors that led to false-positive novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgM detection results using gold immunochromatography assay (GICA) and enzyme-linked immunosorbent assay (ELISA) and the corresponding solutions. GICA and ELISA were used to detect SARS-CoV-2 IgM in 86 serum samples, including 5 influenza A virus (Flu A) IgM-positive sera, 5 influenza B virus (Flu B) IgM-positive sera, 5 Mycoplasma pneumoniae IgM-positive sera, 5 Legionella pneumophila IgM-positive sera, 6 sera of HIV infection patients, 36 rheumatoid factor IgM (RF-IgM)-positive sera, 5 sera from hypertensive patients, 5 sera from diabetes mellitus patients, and 14 sera from novel coronavirus infection disease 19 (COVID-19) patients. The interference factors causing false-positive reactivity with the two methods were analyzed, and the urea dissociation test was employed to dissociate the SARS-CoV-2 IgM-positive serum using the best dissociation concentration. The two methods detected positive SARS-CoV-2 IgM in 22 mid-to-high-level-RF-IgM-positive sera and 14 sera from COVID-19 patients; the other 50 sera were negative. At a urea dissociation concentration of 6 mol/liter, SARS-CoV-2 IgM results were positive in 1 mid-to-high-level-RF-IgM-positive serum and in 14 COVID-19 patient sera detected using GICA. At a urea dissociation concentration of 4 mol/liter and with affinity index (AI) levels lower than 0.371 set to negative, SARS-CoV-2 IgM results were positive in 3 mid-to-high-level-RF-IgM-positive sera and in 14 COVID-19 patient sera detected using ELISA. The presence of RF-IgM at mid-to-high levels could lead to false-positive reactivity of SARS-CoV-2 IgM detected using GICA and ELISA, and urea dissociation tests would be helpful in reducing SARS-CoV-2 IgM false-positive results.
Search related documents:
Co phrase search for related documents- accurate diagnosis and acid detection nucleic: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- accurate diagnosis and acute disease: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- accurate diagnosis and acute disease detection: 1
- accurate diagnosis and acute phase: 1, 2, 3, 4, 5, 6, 7, 8, 9
- accurate diagnosis and lymphocyte count: 1, 2
- accurate timely and acid detection: 1, 2, 3, 4, 5
- accurate timely and acid detection nucleic: 1, 2, 3, 4, 5
- accurate timely and acute disease: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
- accurate timely and acute phase: 1, 2, 3
- accurate timely and lymphocyte count: 1
- accurate timely diagnosis and acid detection: 1, 2
- accurate timely diagnosis and acid detection nucleic: 1, 2
- accurate timely diagnosis and acute disease: 1, 2, 3, 4, 5, 6, 7, 8
- accurate timely diagnosis and acute phase: 1, 2
- acid detection and acute disease: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acid detection and acute disease detection: 1
- acid detection and acute phase: 1, 2, 3
- acid detection and low throughput: 1
- acid detection and lymphocyte count: 1, 2, 3, 4, 5, 6, 7, 8, 9
Co phrase search for related documents, hyperlinks ordered by date