Author: Corman, V M; Eckerle, I; Bleicker, T; Zaki, A; Landt, O; Eschbach-Bludau, M; van Boheemen, S; Gopal, R; Ballhause, M; Bestebroer, T M; Muth, D; Müller, M A; Drexler, J F; Zambon, M; Osterhaus, A D; Fouchier, R M; Drosten, C
Title: Detection of a novel human coronavirus by real-time reverse-transcription polymerase chain reaction. Cord-id: vlhzhv0m Document date: 2012_1_1
ID: vlhzhv0m
Snippet: We present two real-time reverse-transcription polymerase chain reaction assays for a novel human coronavirus (CoV), targeting regions upstream of the E gene (upE) or within open reading frame (ORF)1b, respectively. Sensitivity for upE is 3.4 copies per reaction (95% confidence interval (CI): 2.5–6.9 copies) or 291 copies/mL of sample. No cross-reactivity was observed with coronaviruses OC43, NL63, 229E, SARS-CoV, nor with 92 clinical specimens containing common human respiratory viruses. We r
Document: We present two real-time reverse-transcription polymerase chain reaction assays for a novel human coronavirus (CoV), targeting regions upstream of the E gene (upE) or within open reading frame (ORF)1b, respectively. Sensitivity for upE is 3.4 copies per reaction (95% confidence interval (CI): 2.5–6.9 copies) or 291 copies/mL of sample. No cross-reactivity was observed with coronaviruses OC43, NL63, 229E, SARS-CoV, nor with 92 clinical specimens containing common human respiratory viruses. We recommend using upE for screening and ORF1b for confirmation.