Selected article for: "hematoxylin eosin and IHC stain"

Author: Rugge, Massimo; Sacchi, Diana; Genta, Robert M; Zanco, Francesca; Guzzinati, Stefano; Pizzi, Marco; Fassan, Matteo; Sabatino, Antonio Di; El-Serag, Hashem
Title: Histological assessment of gastric pseudopyloric metaplasia: Intra- and inter-observer consistency.
  • Cord-id: ytxnu3n1
  • Document date: 2020_9_28
  • ID: ytxnu3n1
    Snippet: BACKGROUND The histological spectrum of oxyntic mucosal atrophy (a major determinant of gastric cancer risk) includes pseudopyloric metaplasia (PPM), which histological assessment has been regarded as unreliable. PPM consistently expresses Trefoil-Factor 2 (TFF2), which is histochemically detecteble (TFF2-IHC). AIMS Intra- and inter-observer consistency in assessing PPM was examined using both hematoxylin & eosin (H&E) and TFF2-IHC. MATERIALS AND METHODS Seventy-four oxyntic biopsy samples obtai
    Document: BACKGROUND The histological spectrum of oxyntic mucosal atrophy (a major determinant of gastric cancer risk) includes pseudopyloric metaplasia (PPM), which histological assessment has been regarded as unreliable. PPM consistently expresses Trefoil-Factor 2 (TFF2), which is histochemically detecteble (TFF2-IHC). AIMS Intra- and inter-observer consistency in assessing PPM was examined using both hematoxylin & eosin (H&E) and TFF2-IHC. MATERIALS AND METHODS Seventy-four oxyntic biopsy samples obtained from autoimmune gastritis were considered. Two serial histological sections obtained from the paraffin-embedded tissue-samples were stained with H&E and TFF2-IHC. Three pathologists (Alpha, Beta, Gamma) independently scored PPM by both staining and the Intra- and inter-observer consistency (H&E versus TFF2-IHC) was calculated using k-statistics and/or Spearman's coefficient. RESULTS Based on H&E-stain versus TFF2-IHC, intra-observer consistency in PPM assessement was ranked as consistently "good" (k-values: Alpha=0.79; Beta=0.78; Gamma=0.75). Based on H&E, the overall PPM inter-observer consistency among the 3 observers was ranked as "good" (k=0.77) (the inter-observer consistency for pairs of observers was as follows: Alpha versus Beta k=0.88; Alpha versus Gamma k=0.87; Beta versus Gamma k=0.80). Based on TFF2-IHC, the overall PPM inter-observer agreement was ranked as "excellent" (k=0.91) (the inter-observer consistency for pairs of observers was as follows: Alpha versus Beta k=1; Alpha versus Gamma k=0.91; Beta versus Gamma k=0.91). CONCLUSION Relying on either H&E staining or TFF2-IHC, pathologists assess PPM consistently.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date