Selected article for: "accurate rapid and low specificity"

Author: Österdahl, Marc F.; Lee, Karla A.; Lochlainn, Mary Ni; Wilson, Stuart; Douthwaite, Sam; Horsfall, Rachel; Sheedy, Alyce; Goldenberg, Simon D.; Stanley, Christopher J.; Spector, Tim D.; Steves, Claire J.
Title: Detecting SARS-CoV-2 at point of care: preliminary data comparing loop-mediated isothermal amplification (LAMP) to polymerase chain reaction (PCR)
  • Cord-id: aw5849rc
  • Document date: 2020_10_20
  • ID: aw5849rc
    Snippet: BACKGROUND: A cost effective and efficient diagnostic tool for COVID-19 as near to the point of care (PoC) as possible would be a game changer in the current pandemic. We tested reverse transcription loop mediated isothermal amplification (RT-LAMP), a method which can produce results in under 30 min, alongside standard methods in a real-life clinical setting. METHODS: This prospective service improvement project piloted an RT-LAMP method on nasal and pharyngeal swabs on 21 residents of a high de
    Document: BACKGROUND: A cost effective and efficient diagnostic tool for COVID-19 as near to the point of care (PoC) as possible would be a game changer in the current pandemic. We tested reverse transcription loop mediated isothermal amplification (RT-LAMP), a method which can produce results in under 30 min, alongside standard methods in a real-life clinical setting. METHODS: This prospective service improvement project piloted an RT-LAMP method on nasal and pharyngeal swabs on 21 residents of a high dependency care home, with two index COVID-19 cases, and compared it to multiplex tandem reverse transcription polymerase chain reaction (RT-PCR). We recorded vital signs of patients to correlate clinical and laboratory information and calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of a single swab using RT-LAMP compared with the current standard, RT-PCR, as per Standards for Reporting Diagnostic Accuracy Studies (STARD) guidelines. RESULTS: The novel method accurately detected 8/10 RT-PCR positive cases and identified a further 3 positive cases. Eight further cases were negative using both methods. Using repeated RT-PCR as a “gold standard”, the sensitivity and specificity of a single novel test were 80 and 73% respectively. PPV was 73% and NPV was 83%. Incorporating retesting of low signal RT-LAMP positives improved the specificity to 100%. We also speculate that hypothermia may be a significant early clinical sign of COVID-19. CONCLUSIONS: RT-LAMP testing for SARS-CoV-2 was found to be promising, fast and to work equivalently to RT-PCR methods. RT-LAMP has the potential to transform COVID-19 detection, bringing rapid and accurate testing to the PoC. RT-LAMP could be deployed in mobile community testing units, care homes and hospitals to detect disease early and prevent spread.

    Search related documents:
    Co phrase search for related documents
    • access lack and loop mediated isothermal amplification: 1
    • access lack and low positive: 1
    • accurate rapid and loop mediated: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • accurate rapid and loop mediated isothermal amplification: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • accurate rapid and low positive: 1, 2, 3, 4, 5, 6, 7
    • accurate rapid testing and loop mediated: 1, 2, 3, 4, 5, 6
    • accurate rapid testing and loop mediated isothermal amplification: 1, 2, 3, 4, 5, 6
    • additional swab and low positive: 1
    • loop mediated and low positive: 1, 2
    • loop mediated isothermal amplification and low positive: 1, 2