Title: Toilets dominate environmental detection of SARS-CoV-2 virus in a hospital
  • Document date: 2020_4_7
  • ID: bkh6j3h4_20
    Snippet: The 5 th floor has a fan coil air-conditioning system with an outdoor-air supply. Two fans deliver 1000 m 3 /h and 8500 m 3 /h (2300 L/s) outdoor air to the non-patient and patient rooms, respectively. No ventilation is provided to the corridor, and a positive pressure is maintained at the nursing station, with no exhaust. According to the original design, each of the 19 isolation rooms is provided with an average of 47 L/s of outdoor air (2.0 AC.....
    Document: The 5 th floor has a fan coil air-conditioning system with an outdoor-air supply. Two fans deliver 1000 m 3 /h and 8500 m 3 /h (2300 L/s) outdoor air to the non-patient and patient rooms, respectively. No ventilation is provided to the corridor, and a positive pressure is maintained at the nursing station, with no exhaust. According to the original design, each of the 19 isolation rooms is provided with an average of 47 L/s of outdoor air (2.0 ACH). The exhaustair fan in the bathroom of each isolation room operates continuously, creating a negative pressure in the ward. Based on the CO2 data, the outdoor air-supply rate was calculated to be 64 L/s (2.5 ACH). The airflow pattern was found to lead from the corridor to each isolation room, and to subsequently exhaust via the bathroom.

    Search related documents:
    Co phrase search for related documents
    • air conditioning and bathroom exhaust: 1
    • air conditioning and fan coil: 1
    • air conditioning and isolation room: 1, 2, 3, 4, 5, 6, 7
    • air conditioning and negative pressure: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • air conditioning and nursing station: 1, 2
    • air conditioning system and airflow pattern: 1, 2
    • air conditioning system and bathroom exhaust: 1
    • air conditioning system and isolation room: 1, 2, 3
    • air conditioning system and negative pressure: 1, 2, 3, 4, 5
    • air conditioning system and nursing station: 1
    • air supply and isolation room: 1, 2, 3, 4, 5
    • air supply and negative pressure: 1, 2, 3, 4
    • air supply rate and isolation room: 1
    • air supply rate and negative pressure: 1
    • airflow pattern and bathroom exhaust: 1
    • airflow pattern and isolation room: 1, 2, 3
    • airflow pattern and negative pressure: 1, 2, 3
    • airflow pattern and nursing station: 1
    • airflow pattern and original design: 1